Under the 2024 IRC, who may grant an individual code modification when special circumstances make strict compliance impractical and the proposal meets the code’s intent and safety requirements?
General Administration
Question · Easy
An inspector receives plans for a replacement furnace. What should be verified before checking the installed work?
Flashcard
Under 2024 IRC R106.1, what format is required for construction documents submitted with a permit application, unless the building official waives the documents?
Question · Medium
Approval that an owner or authorized agent must obtain from the building official before installing or replacing a regulated mechanical system.
Guess the Term
Chapter 1: General Administration & Requirements
1.1 Administrative Provisions, Permits, and Inspections
Study guide
Cheat sheet
Which of these buildings falls outside the ordinary scope of 2024 IRC R101.2?
Read the clue and guess the term in 6 tries.
Game
Who decides whether a proposed alternative mechanical installation meets the code's intent?
A permit submittal relies on a product listing to show compliance. Under 2024 IRC R104.2.1, what can the building official require to verify the listed product’s installation?
Request claiming that a code or its adopted rules were incorrectly interpreted; the board hearing it may not waive the requirements.
Under 2024 IRC M1307.3, how far above a garage floor must a nonexempt appliance’s ignition source be elevated?
Heating Cooling Water Heaters
A permit drawing conflicts with the equipment listing. Which document must the inspector resolve before approval?
A mechanical appliance is installed where a vehicle could strike it in a garage. What does 2024 IRC M1307.3.1 require at that location?
Requirement that heating and cooling equipment be placed so its filters, blowers, motors and controls can be reached for servicing and replacement.
Heating, Cooling & Water Heaters
1.2 General Mechanical Requirements, Labeling, and Access
Under 2024 IRC M1305.1.2, how wide must the continuous solid flooring along the required passageway to an attic appliance be?
Swap tiles to line up three of the same term.
Term Match
What is the inspection consequence when a manufacturer's required service clearance is blocked?
Under 2024 IRC M1305.1.3, what are the minimum rough-framed dimensions of the underfloor appliance access opening, before accounting for the size of the appliance?
Air chamber on the supply side of a warm-air furnace where a cooling coil may sit; if it does, the blower must be rated for at least 0.5-inch water column unless the furnace is listed for the coil.
Under the general 2024 IRC appliance servicing rule, where is a level working space at least 30 inches deep and 30 inches wide required?
Why should an M1 inspector distinguish the model IRC from a local adopted code?
Which ACCA manuals does 2024 IRC M1401.3 name for equipment selection and building load calculations, respectively?
Appliance that circulates hot water for heating purposes and must have a pressure gauge and a temperature gauge, or a combined gauge, showing the normal operating range.
1.3 Equipment Clearances and Safety Controls
Under 2024 IRC M1411.9.2, what is the minimum nominal diameter for a cooling-coil condensate drain serving one unit?
Flip two cards at a time to find matching terms.
Term Pairs
A furnace is replaced with a unit of different capacity. What air-distribution issue must be rechecked?
Heating, Cooling and Water Heaters
Under 2024 IRC M1411.9.1, which installation requires secondary condensate protection because overflow or a blocked primary drain would damage building components?
Question · Hard
Component at an appliance that receives fuel and is shut off by a flame safeguard when its ignition source fails.
Under 2024 IRC M1411.4, which field-installed accessory is prohibited in the ductwork of a Group A2L refrigeration system?
An appliance is installed in an attic. What is the inspector's access question?
A boiler is installed in an IRC flood hazard area without using the ASCE 24 equipment protection exception. What elevation requirement applies under 2024 IRC M2001.4 and R306.1.6?
Pressure ___ valve on a boiler, set at the unit's maximum rating and rated for the equipment served.
Chapter 2: Heating, Cooling & Water Heaters
2.1 Forced-Air Heating Systems and Furnaces
Under 2024 IRC M1411.9.1, what is the minimum depth of an auxiliary condensate drain pan where one is used to protect a cooling coil?
Find five hidden terms in a grid of letters.
Term Search
Why inspect cooling equipment’s condensate route instead of only its refrigerant lines?
In Seismic Design Category D1, what does 2024 IRC M1307.2 require for a storage water heater?
Appliance whose exhaust duct must end outdoors with a backdraft damper and no screen and, under the specified-length method, run no more than 35 feet from the transition duct connection to the outlet terminal.
Exhaust & Ventilation Systems
In addition to the manufacturer’s instructions and other applicable code provisions, what IRC chapter does 2024 IRC M2005.1 specifically require for water heater installations?
What does an inspector verify when a water heater is placed beside stored combustibles?
Under 2024 IRC P2804.6.1, what is the maximum height for a water heater relief discharge pipe ending above a floor or the flood-level rim of a waste receptor?
Metal exhaust canopy over a domestic open-top broiler, required to be at least No. 28 gage and to extend across the whole unit.