Per the 2024 IMC, who has the authority to enforce the provisions of the International Mechanical Code?
General Administration
Question · Easy
According to the 2024 IMC, construction documents submitted for plan review must include which of the following for mechanical systems?
Per the 2024 IMC, how long must approved construction documents be retained by the code official after the work is complete?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which code primarily governs the design and installation of fuel gas piping and gas-fired appliances during commercial plan review?
Per IMC Chapter 2, the term 'environmental air' refers to:
Per the 2024 IMC, when is a mechanical permit required?
Per IMC 304.1, mechanical systems and equipment must be installed in accordance with:
General Regulations
Per IMC 306.3, what is the minimum unobstructed passageway width to an appliance located in an attic?
Per IMC 306.3, the length of a passageway to an appliance in an attic shall not exceed what distance, measured from the passageway opening?
Per IMC 306.5, an unobstructed working space of at least what minimum dimensions must be provided in front of the service side of appliances located on roofs?
Per IMC 307.2.1, condensate from cooling coils and evaporators must discharge to:
Per IMC 307.2.2, an auxiliary drain pan must be provided where a condensate overflow would cause damage to which of the following?
Per IMC 308.1, clearances from combustible materials to appliances must comply with:
Per IMC 309.1, the required air temperature for heating occupied spaces at a point 3 feet above the floor and 2 feet from exterior walls is:
Per the 2024 IMC 403.3.2.1, mechanical ventilation shall be provided for occupied spaces in accordance with which table?
Exhaust And Ventilation
Per IMC Table 403.3.1.1 (2024), the people outdoor air rate for an office space is approximately:
Question · Hard
An office has an occupant load of 40 people and a floor area of 4,000 square feet. Using IMC Table 403.3.1.1 with Rp = 5 cfm/person and Ra = 0.06 cfm/sq ft, what is the minimum required breathing-zone outdoor air?
Per IMC 403.3.2.1, mechanical ventilation systems serving spaces with a high occupant density must include which of the following controls where required by the code?
Per IMC 401.4, the outdoor air intake opening must be located a minimum of how many feet above grade?
Per IMC 401.4, outdoor intake openings must be located a minimum of how many feet from any hazardous or noxious contaminant source?
Per IMC 403.2.1, bathrooms and toilet rooms must be mechanically ventilated at a minimum exhaust rate of:
Per IMC 404.1, enclosed parking garages must be mechanically ventilated at a minimum rate of:
Per IMC 504.6 (2024), the maximum developed length of a residential clothes dryer exhaust duct is:
Per IMC 504.8, clothes dryer exhaust ducts must terminate at least how many feet from any opening into a building?
Per IMC 506.3.10 (2024), the minimum air velocity in a Type I kitchen exhaust hood duct must be:
Per IMC 507.1, commercial kitchen exhaust hoods are classified as Type I or Type II. Type I hoods are required over cooking appliances that produce:
A commercial kitchen has a 12-foot-long Type I wall-canopy hood over medium-duty cooking equipment. Per IMC Table 507.13 with a 300 cfm/linear foot rate, what is the minimum net exhaust rate?
Per IMC 508.1 (2024), replacement air for commercial kitchen hoods must be provided at a rate approximately equal to:
Per IMC 507.2.3, a Type I hood is not required over an appliance producing grease vapors if the appliance is listed for:
Per IMC 506.3.11.1, Type I (grease) duct horizontal slope must be not less than:
Per IMC 506.3.9 (2021) / 506.3.12.3 (2024), cleanouts serving horizontal sections of grease ducts shall be spaced not more than:
Per IMC 505.2, domestic cooking exhaust (residential range hood) must terminate outside the building with a minimum duct size typically no less than:
Per IMC 502.9.1, hazardous exhaust system ducts must be constructed of which material?
Per IMC 403.3.1.1, the area outdoor air rate for a classroom (5-8 years) is:
Per IMC 601.2, a plenum is defined as:
Duct Systems
Per IMC 602.2.1, materials exposed within plenums must have a flame spread index not exceeding:
Per IMC 603.4 and Table 603.4, the minimum thickness of rectangular galvanized steel duct with a maximum dimension between 13 and 30 inches is:
Per IMC 603.6, factory-made air ducts must be listed and labeled in accordance with:
Per IMC 603.9, flexible air connectors are limited to a maximum length of:
Per IMC 607.2, a fire damper is required where ducts penetrate:
Per IMC 607.3.1, fire dampers must bear a label indicating compliance with:
Per IMC 607.5.4, duct systems penetrating a corridor wall in a fully sprinklered Group B building require:
Per IMC 603.17.1, duct systems shall be insulated as required by the:
Per IMC 603.10, duct systems must be designed and installed to prevent:
Per IMC 603.1, ducts installed within walls, floors, and ceilings must have a smoke-developed index not exceeding:
Per IMC 603.5, underground duct systems must be:
Per IMC 603.17.2, duct joints, seams, and connections must be sealed to comply with the: