Per the IBC, which document establishes the legal authority of the building official to review construction documents and issue permits?
General Administration
Question · Easy
Building Official's Interpretive Authority
Flashcard
Under IBC Section 107, which of the following is generally required as part of the submitted construction documents for a commercial building permit?
Chapter 1: Administration, Legal Authority & Plan Review Workflow
1.1 Scope, Code Applicability & Administrative Authority
Study guide
Cheat sheet
According to IBC Chapter 1, how long is a permit generally valid before becoming invalid if work has not commenced?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Special Inspection vs. Structural Observation
Per IBC 107.5, how long must the building official retain one set of approved construction documents?
Question · Hard
In the 2021 IBC, which section allows the building official to approve alternative materials, design, and methods of construction not specifically prescribed by the code?
Construction Documents and the Rest of the Submittal
A 6,000 sq ft coffee shop with seating for 110 customers would be classified under which IBC occupancy group?
Building Planning
1.2 Permit Submittal Documents & Plan Review Standards
Per IBC 308.2, a residential care facility housing 20 ambulatory residents who need personal care services is classified as which occupancy group?
Why Occupancy Classification Drives the Code
Occupancy Classification
Per IBC Table 601, what is the minimum required fire-resistance rating for structural frame members in Type IIA construction?
A Group B office building of Type IIB construction is proposed. With no sprinklers, what is the maximum number of stories above grade plane permitted by IBC Table 504.4?
Mixed Occupancy Options
When two occupancy groups are located in the same building and not separated by fire barriers, what method does IBC 508.3 allow for compliance?
1.3 Alternative Materials, Design Approvals & Special Inspections Administration
Per IBC 508.2, an accessory occupancy must not exceed what percentage of the floor area of the story in which it is located?
Accessory Occupancy
Per IBC 403, a high-rise building is defined as a building with an occupied floor located how far above the lowest level of fire department vehicle access?
Per IBC 707, which of the following best describes the purpose of a fire barrier?
Public Safety And Special Construction
Construction Types I–V Overview
Construction Types & Allowable Height/Area
Per IBC 706.2, a fire wall must be designed and constructed to perform in which way under fire conditions?
Chapter 2: Occupancy Classification & Special Use Requirements
2.1 Occupancy Groups A through U Classification
Per IBC Table 716.1(2), what is the minimum fire protection rating of a fire door in a 2-hour fire barrier enclosing an interior exit stairway?
What Sets Allowable Height and Area
An exit enclosure serving four stories in a building must have what minimum fire-resistance rating per IBC 1023.2?
Per IBC 713.4, a shaft enclosure connecting four or more stories must have a fire-resistance rating of not less than:
Fire Separation Distance
Per IBC 708.3, unless an exception applies, a fire partition separating tenant spaces in a covered mall building must have a fire-resistance rating of not less than:
2.2 Mixed Occupancy Principles: Separated, Nonseparated & Accessory Uses
Per IBC Table 1020.2, the minimum corridor fire-resistance rating for a Group B occupancy with sprinklers and an occupant load greater than 30 is:
Unlimited Area Building
Per IBC 705.5, when the fire separation distance between a Type VB building and the assumed property line is 8 feet, what is the minimum exterior wall fire-resistance rating (for other than Group H)?
Per IBC 705.8, exterior walls with a fire separation distance of less than 3 feet shall have openings that are:
Safeguards During Construction
Building Planning — Special Uses
Per IBC 712, which of the following is NOT an acceptable method to interconnect two stories without requiring a shaft enclosure?
2.3 Special Detailed Requirements: Atriums, High-Rise, Underground & Hazardous Uses
Per IBC 717.5, a listed fire damper is required where a duct penetrates which of the following?
Special Detailed Requirements by Occupancy