Which chapter of the International Building Code (IBC) contains the primary scoping provisions for accessibility in new construction?
Scoping Provisions
Question · Easy
Which referenced standard provides the technical criteria for accessible design used with the IBC?
Chapter 1: General Administrative and Scoping Provisions
1.1 Occupancy Group Accessibility and IBC Chapter 11 Scoping
Study guide
Which occupancy group contains dwelling and sleeping units subject to Type A and Type B unit scoping in IBC Section 1107?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
In a Group R-2 apartment building containing 50 dwelling units, what is the minimum number of Type A dwelling units required by the IBC?
When existing buildings undergo alterations, which of the following provisions generally applies regarding accessibility?
Question · Hard
Per the IBC, the accessibility requirements of Chapter 11 do NOT apply to which of the following?
1.2 General Administration: Definitions, Conventions, and Code Editions
In a building with multiple stories, which of the following generally requires an accessible means of egress from each accessible occupied portion?
Per ICC A117.1-2017 for new buildings and facilities, what is the required minimum diameter of a circular turning space for a wheelchair?
Building Blocks
Per ICC A117.1-2017 for new buildings and facilities, what is the minimum clear floor space required to accommodate a single stationary wheelchair user?
Per ICC A117.1 Section 308, what is the maximum allowable unobstructed high forward reach for a wheelchair user?
1.3 Existing Buildings: IEBC Section 306 Alterations, Additions, and Changes of Occupancy
Per ICC A117.1, what is the minimum low forward or side reach height for a wheelchair user?
Changes in level on an accessible route with a vertical rise of 1/4 inch or less can be treated how?
Per ICC A117.1 Section 306.3, what is the minimum height of the knee clearance space required under an accessible element (such as a lavatory or dining surface) at the front edge?
Per ICC A117.1 Section 306.2, where toe clearance is required beneath an element as part of a clear floor space, the toe clearance shall extend a minimum of how many inches deep beneath the element?
1.4 Technical Infeasibility, Existing-Building Ramps, and Historic Structures
Per ICC A117.1, what is the maximum permissible opening in a floor grating along an accessible route (measured in the direction of travel)?
Per ICC A117.1, carpeting on an accessible route must meet which of the following requirements?
Per ICC A117.1, the maximum unobstructed high side reach for a wheelchair user is:
A protruding object must not reduce the required accessible route width. Per ICC A117.1, objects mounted between 27 inches and 80 inches above the floor may protrude a maximum of how many inches into the circulation path?
Chapter 2: Building Blocks (ICC A117.1 Chapter 3)
2.1 Walking and Floor Surfaces, Openings, and Level Changes
Per ICC A117.1 Section 307, what minimum vertical clearance must be provided at circulation paths?
Per ICC A117.1, operable parts of controls and dispensers that must be accessible shall be operable with one hand and shall NOT require which of the following?
Per ICC A117.1, the minimum clear width of an accessible route is 36 inches. This width may be reduced to 32 inches clear only for a maximum length of how much?
Accessible Routes
Per ICC A117.1, what is the minimum clear width for a hinged door when the door is open 90 degrees?
2.2 Turning Space and Clear Floor Space: New Versus Existing Buildings
Per ICC A117.1, the maximum slope allowed for a ramp run in new construction (with a rise greater than 6 inches) is:
Per ICC A117.1, what is the maximum rise of a single ramp run before an intermediate landing is required?
Per ICC A117.1, ramp landings must be at least how long in the direction of travel?
Per ICC A117.1, ramps with a rise greater than 6 inches must have handrails on:
2.3 Knee and Toe Clearances
Per ICC A117.1, the cross slope of an accessible route walking surface, exclusive of ramps, shall not exceed:
Per ICC A117.1, the maximum opening force for interior hinged doors (other than fire doors) along an accessible route is:
Per ICC A117.1, doors with closers shall be adjusted so that from an open position of 90 degrees the time required to move to a point 12 degrees from the latch is a minimum of:
Per ICC A117.1 Table 404.2.3.2, for a front approach to a hinged door on the pull side, the minimum maneuvering clearance perpendicular to the door is:
2.4 Unobstructed and Obstructed Reach Ranges
Per ICC A117.1, the threshold at doorways shall be a maximum of what height?
Per ICC A117.1, the minimum inside clear dimensions of a standard accessible elevator car are:
Per ICC A117.1, the clear width of an elevator hoistway door opening on an accessible elevator must be a minimum of:
Curb ramps that are part of an accessible route must have a running slope not steeper than:
2.5 Protruding Objects and Vertical Clearance
Per ICC A117.1, the minimum width of a curb ramp, exclusive of flared sides, is:
An accessible route that connects accessible building or facility entrances with interior and exterior spaces must coincide with, or be located in the same area as, the general:
Per IBC Section 1105, at least what percentage of public entrances to a building must be accessible?
Per ICC A117.1, stairs that are part of a required accessible means of egress must have nosings that: