Under the Uniform Plumbing Code (UPC), which officer has the authority to interpret the code and enforce it within a jurisdiction?
General Regulations
Question · Easy
Per UPC definitions, a 'plumbing fixture' is best defined as:
Definitions
Under the UPC, 'drainage fixture units' (DFU) are used primarily to:
Dwv Sizing
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What is the UPC minimum slope of a horizontal drainage pipe that is 3 inches or smaller in diameter?
Sanitary Drainage
Per the UPC, horizontal drainage pipes 4 inches and larger may have a minimum slope of:
Under the UPC, a standard trap seal depth shall not be less than:
Traps And Interceptors
Per the UPC, the maximum distance between a fixture trap weir and its protecting vent for a 2-inch trap arm is generally:
Vents
Question · Hard
A vent stack or stack vent that terminates through a roof must extend above the roof at least how many inches (where snow or traffic is not a concern)?
What is the UPC minimum horizontal distance that a vent terminal must be kept from any door, operable window, or air intake?
Under the UPC, wet venting is an approved method that uses the drain pipe as a vent for which of the following?
An island vent (loop vent) is specifically used for:
A circuit vent under the UPC is used for:
Which trap is PROHIBITED by the UPC?
The maximum vertical distance of a fixture tailpiece from the fixture outlet to the inlet of the trap (often called the tailpiece length) is generally:
Under the UPC, a food service establishment discharging grease-laden waste must be served by which device?
Water supply fixture units (WSFU) are used in UPC to:
Water Pipe Sizing
What minimum pressure at the highest and most remote outlet is typically required by the UPC for fixture supply?
Water Supply And Distribution
When building supply pressure exceeds what value must a pressure-reducing valve be installed per the UPC?
Per the UPC, an approved backflow preventer for a direct-connected lawn irrigation system without chemical injection is typically:
What type of backflow protection is required on a boiler or HVAC system where chemicals may be introduced?
Per the UPC, an air gap used to prevent backflow must be at least:
Under the UPC, the minimum pipe size for the water service from the meter to a typical single-family dwelling with a group of fixtures is generally determined by:
A water heater T&P (temperature and pressure) relief valve discharge must:
Water Heaters
Under the UPC, the maximum hot-water temperature delivered to a tub or shower valve is typically limited by a tempering/listed scald-protection device at:
What is the UPC minimum access clearance required in front of a water heater for service?
A gas water heater installed in a garage must have the ignition source elevated at least how many inches above the floor, unless it is listed as Flammable Vapor Ignition Resistant (FVIR)?
A water heater installed where leakage can damage the building must be provided with:
Cleanouts are required on a building drain per UPC at:
Under the UPC, a cleanout plug installed at the end of a building drain to allow main drain access at grade must provide a minimum clearance of:
A water closet installed on a 3-inch drain has a UPC maximum developed trap arm length of approximately:
What is the minimum fixture unit assignment (DFU) for a water closet with a tank (in the UPC DFU table)?
A vent terminal through a roof used as a walking surface must extend above the roof surface at least:
Under the UPC, a fixture installed as an indirect waste receptor (e.g., an ice machine) must discharge through:
Indirect Waste
A food preparation sink in a commercial kitchen must be served by an indirect waste with what minimum air gap?
The UPC defines a 'building drain' as:
A 'building sewer' extends from the building drain to:
The 'flood level rim' of a fixture is:
Gas piping pressure tests required by the UPC and referenced fuel gas code are typically performed:
Fuel Gas Piping
Under the UPC (and referenced fuel gas code), underground gas piping material commonly allowed includes:
Sizing fuel gas piping under the UPC (referencing NFPA 54 methodology) requires:
Gas Piping Sizing
A gas appliance shutoff valve must be located:
Roof drain and storm drain sizing under UPC is based on which of the following?
Storm Drainage
Under the UPC, combined sewers (sanitary + storm) are:
A fixture flow rate of 1.28 gallons per flush (gpf) is required for water closets by the UPC because:
Fixtures And Fittings
Lavatory faucets in public restrooms are limited under the UPC to a maximum flow rate of:
Under the UPC, showerheads are limited to a maximum flow rate of:
A shower stall interior floor area per UPC must be a minimum of approximately: