Under the Electricity Ordinance (Cap. 406), which voltage range is defined as low voltage (a.c. between conductors)?
Legislation Registration Safety
Question · Easy
Under Cap. 406, extra-low voltage (ELV) a.c. normally does not exceed which value between conductors or between a conductor and earth?
Question · Medium
Grade C electrical work on a low-voltage fixed electrical installation covers which capacity limit?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which installations are excluded from ordinary Grade C electrical work and require a separate Grade R category?
Question · Hard
A fixed electrical installation under Cap. 406 generally excludes which of the following?
Who must be registered with EMSD to carry out electrical work on a low-voltage or high-voltage fixed electrical installation in Hong Kong?
For the Examination for Registration as a Grade C Electrical Worker, what is the official Part A pass mark?
Which certificate is used to certify a newly completed fixed electrical installation (or major alteration) after design, inspection and testing?
Before working on a low-voltage fixed installation, which safety practice is most consistent with assuring electrical safety at work?
Periodic testing and certification of fixed electrical installations in Hong Kong is primarily required to:
The severity of electric shock injury depends mainly on which combination of factors?
Electric Shock Emf Fire
Which practice best reduces the risk of electricity-related fire from overloaded final circuits?
Electromagnetic fields around power-frequency electrical installations are primarily associated with:
After a serious electrical accident on a fixed installation, which action should come first once immediate life-saving measures and making the scene safe are addressed?
Which condition most strongly indicates a possible electrical fire risk from a loose connection?
In the IEE/BS earthing-arrangement classification, what does the first letter 'T' in TN-S indicate?
Earthing Protective Conductors
In a TN-S system, which statement is correct?
Hong Kong low-voltage public supply practice is commonly described as which earthing arrangement family?
A circuit protective conductor (CPC) is mainly used to:
For Class I equipment, protection against electric shock depends on:
Which of the following cannot serve as a protective conductor against earth leakage faults?
Earth-fault loop impedance (Zs) is important mainly because it determines:
Main equipotential bonding is primarily intended to:
An earth electrode for an electrical installation should be selected and installed so that:
Supplementary bonding in a bathroom is used mainly to:
If the protective conductor to a Class I metal-clad item is open-circuit, the main immediate risk under an internal live-to-case fault is:
Which statement about PEN conductors is correct?
The rationale for sizing a live conductor on current-carrying capacity is mainly to:
Cables Voltage Drop Circuits
For a circuit protected by a fuse to BS 88, which relationship among design current Ib, protective-device rating In and conductor capacity Iz is required?
Voltage drop on a final circuit should be limited mainly so that:
Grouping many cables together without derating primarily risks:
Diversity factor in load estimation is used to:
Which wiring enclosure is non-metallic and therefore cannot be used as a protective conductor?
Circuit categories and segregation rules exist mainly to:
Hong Kong's normal low-voltage public supply voltages are commonly:
In a star-connected three-phase four-wire system, the line voltage is related to the phase voltage by approximately:
Busbar trunking systems are often selected for rising mains and heavy distribution because they:
Temporary electricity supplies on construction sites require particular care mainly because:
Power factor of an installation is important in cable and supply sizing because a lower lagging power factor:
The current rating of a protective device is the current which:
Overcurrent Earth Fault Protection
Overload current is best described as:
Short-circuit current differs from overload mainly because it:
Protection against electric shock from direct contact (basic protection) primarily prevents:
Automatic disconnection of supply on an earth fault is a key method of:
Discrimination (selectivity) between two fuses in series is achieved when:
An RCD (residual current device) operates principally by detecting:
The breaking capacity of a circuit breaker must be at least equal to: