Under the Electricity Ordinance (Cap. 406), Grade B electrical work covers low-voltage fixed installations with maximum demand not exceeding:
General Knowledge Ee Theory
Question · Easy
The HKEAA Grade B registration examination Part A consists of how many multiple-choice questions, and what is the pass mark?
For the Grade B registration examination Part B, the official pass requirement is:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
The total official Grade B registration examination (Part A plus Part B) contains:
The Code of Practice for the Electricity (Wiring) Regulations in Hong Kong is issued primarily to:
Ohm's law for a purely resistive circuit states that voltage equals:
In a balanced three-phase star-connected load, the line voltage VL relates to phase voltage Vph by:
Question · Hard
Kirchhoff's Current Law (KCL) at a node in an electrical network requires that:
Question · Medium
The RMS value of a sinusoidal alternating current is related to its peak value Ip by:
The average value of a full-cycle sinusoidal voltage is:
In a balanced three-phase system, total active power P (watts) is given by:
Apparent power S in a three-phase circuit equals:
Reactive power Q in a three-phase inductive load is calculated as:
Power factor is defined as:
When converting a three-phase delta-connected network to an equivalent star for analysis, each star leg resistance equals:
Thevenin's theorem replaces a linear network seen from two terminals with:
Using the adiabatic equation S = √(I²t)/k, a fault current of 315 A for 1.2 s with k = 115 (copper PVC) gives minimum CPC cross-sectional area approximately:
Compared with Grade A, a registered Grade B electrical worker may carry out LV fixed installation work up to:
Under the Electricity (Registration) Regulations, a Registered Electrical Worker (REW) is primarily responsible for:
In a balanced delta-connected three-phase load, line current IL relates to phase current Iph by:
Two resistors of 6 Ω and 3 Ω are connected in parallel. The equivalent resistance is:
The Electricity (Wiring) Regulations are subsidiary legislation under:
When selecting cable size for a final circuit, the CoP requires consideration of:
Cables Protection Circuits
Grouping several current-carrying cables in one conduit typically requires:
Excessive voltage drop in a final circuit primarily causes:
Main protective bonding conductors connect extraneous conductive parts to:
Socket-outlets in a bathroom zone typically require additional protection by:
Discrimination (selectivity) between protective devices means:
Earth-fault loop impedance Zs must be low enough to ensure:
A residual current device (RCD) detects:
Rising mains (busbar riser) installations in high-rise buildings require attention to:
Temporary electrical supplies on construction sites should:
The breaking capacity of a circuit-breaker must be:
Cable joints in accessible locations must be:
Minimum clearance between overhead lines and structures is specified to prevent:
Basic protection against electric shock means preventing contact with:
Fault protection against electric shock relies on:
Kitchen ring final circuits in Hong Kong installations typically use:
Electricity metering equipment must be installed:
Busbar trunking systems must be assessed for:
Miniature circuit-breakers (MCBs) provide protection primarily against:
Protective relays on LV switchgear are used to:
Segregation of different circuit categories in trunking requires:
Earth electrodes in a TT system provide:
When two identical cables are run in parallel for the same phase:
Arc Fault Detection Devices (AFDD) are intended to mitigate:
IP code (e.g. IP44) indicates: