Which code is the primary installation standard a TSSA Gas Technician 2 applies when installing natural gas and propane appliances and piping in Ontario?
Codes Regulations
Question · Easy
Which CSA code governs propane storage and handling, separate from appliance and piping installation?
Question · Medium
What is the minimum passing grade for TSSA Fuels Safety written certification examinations, including Gas Technician exams?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
A candidate for a TSSA Gas Technician 2 (G.2) certificate must first hold which prerequisite certificate?
Within typical Ontario G.2 practice, a Gas Technician 2 works unsupervised on gas appliances up to approximately what maximum input?
For a TSSA Gas Technician 2/3 Fuels written exam, which statement about reference materials is correct?
If a Fuels candidate fails a TSSA multiple-choice examination, when are they typically eligible to re-write?
Before installing a gas appliance, a G2 technician must verify the equipment is approved. Which evidence best confirms approval for use in Canada/Ontario?
What is the primary purpose of a drip leg (dirt pocket) installed in a gas supply line ahead of an appliance?
Advanced Piping Tubing
When sizing gas piping or tubing for an appliance system, the technician must primarily ensure that:
Which joint method is generally appropriate for connecting steel gas pipe in a typical indoor distribution system (where permitted by code and local practice)?
After assembling new gas piping, what must be completed before placing the system into service?
Why must gas piping be adequately supported along its length?
Which statement about CSST (corrugated stainless steel tubing) gas systems is most accurate for G2 practice?
Question · Hard
A shut-off valve serving a gas appliance should be located so that it is:
When two underground utilities cross, gas piping clearance practice is intended primarily to:
In a typical residential gas furnace control circuit, the thermostat commonly switches which voltage?
Basic Electricity
A fuse or circuit breaker in a gas appliance branch circuit is primarily intended to:
If two identical resistive loads are connected in parallel across a 24 V transformer, compared with one load alone the transformer secondary current will:
A continuity test with power removed is most appropriate to check whether:
Which statement best describes a step-down control transformer used on gas appliances?
Polarity and grounding faults on a gas appliance electrical supply can cause:
Ohm’s law relates voltage (V), current (I), and resistance (R) as:
A standing-pilot thermocouple typically generates approximately which open-circuit millivolt range when heated by a proper pilot flame?
Mechanical Electronic Controls
Flame rectification proving systems typically measure flame signal in:
What is the function of a high-limit switch on a forced-air gas furnace?
A rollout switch on a gas furnace is designed to open when:
On many induced-draft furnaces, the pressure switch must close to prove:
A combination gas valve on a modern furnace typically includes:
Intermittent pilot or hot-surface ignition systems improve safety versus continuous standing pilots mainly by:
In Module 13 terms, treating “the building as a system” means recognizing that:
Building As System
Powerful kitchen or dryer exhaust fans can contribute to which combustion-safety problem in a tight house with a natural-draft appliance?
Make-up air provisions are most directly intended to:
Sealed-combustion (direct-vent) appliances are generally less sensitive to house depressurization because:
When diagnosing intermittent CO detector alarms in a home with a natural-draft water heater, a G2 should consider:
Unvented (non-vented) gas heaters release combustion products:
Domestic Nonvented Appliances
Before lighting a newly installed domestic gas range, the technician should verify:
Oxygen depletion sensors (ODS) on certain unvented heaters are intended to:
A domestic gas dryer typically requires which venting practice?
When converting a listed appliance between natural gas and propane, the technician must:
Which hazard is especially associated with indoor use of non-vented gas appliances?
A gas pressure regulator’s main job is to:
Meters Regulators Relief
Over-pressure protection (OPP) devices are installed to:
A relief valve on a propane regulator system must discharge to a location that is:
Clocking a gas meter is used by technicians primarily to:
Typical residential natural gas manifold pressure for many atmospheric appliances is on the order of:
A two-stage propane regulation system typically uses:
Loading more…