Under Ontario Regulation 209/01 (Elevating Devices), what is the maximum time allowed to report an elevating device incident that results in death or serious injury to the TSSA?
Safety And Regulations
Question · Easy
OSHA fall heights, to scale
Short
Which of the following is the first step when performing lockout/tagout (LOTO) on a rack and pinion construction hoist?
Under Ontario's Construction Projects Regulation (O. Reg. 213/91), at what height above the floor or ground is a worker required to wear fall protection equipment if not protected by guardrails?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What is the primary role of a TSSA Elevating Device Inspector on a construction site?
In a standard lockout/tagout procedure, who is authorized to remove a personal safety padlock from a hoist main disconnect?
When working on top of a construction hoist car during erection or maintenance, what is the preferred method of fall protection?
What is the purpose of the 'dead-man' switch or safety controls on a construction hoist?
If a construction hoist experiences a major structural failure but no injuries occur, what is the TSSA notification requirement?
Which license class is required in Ontario to work unsupervised on a construction hoist as an elevating device mechanic?
When working in the hoistway pit, what is a primary safety hazard that a mechanic must guard against?
According to the TSSA Elevating Devices Regulation, how often must a construction hoist undergo a safety inspection by a licensed mechanic?
Question · Medium
When working on the electrical drive motors of a construction hoist, what is the correct location to lock out the system?
Under O. Reg. 209/01, who is responsible for keeping the elevating device logbook up to date on a construction site?
What type of fall protection anchorage point is acceptable when erecting a rack-and-pinion hoist tower?
In the event of a power failure that leaves a personnel hoist stranded between floors, what is the correct procedure for manual lowering?
Under Ontario Regulation 213/91 (Construction Projects), what is the minimum clearance distance that must be maintained between a hoist and live overhead power lines operating at 50,000 volts?
If a fire breaks out in the machine room on top of a construction hoist car, which type of fire extinguisher must be used?
A construction hoist is modified to increase its rated capacity by 10%. Under the Technical Standards and Safety Act, what action is required before this hoist can be placed back in service?
Question · Hard
Under O. Reg. 209/01, if a TSSA inspector issues a Director's Order regarding a safety hazard on a construction hoist, what is the status of that hoist?
During a rescue of workers stranded on a rack-and-pinion hoist, what is the maximum wind speed at which manual lowering of the car top is permitted?
Which Canadian safety standard governs the design, construction, installation, and operation of personnel hoists?
Codes And Standards
Under the CSA Z256 safety standard, which of the following is strictly prohibited on a material hoist?
According to CSA Z185, what is the minimum required height for the enclosure around the base of a personnel hoist?
According to CSA Z185, what must be installed on all landing doors of a personnel hoist to prevent the hoist from operating unless the doors are closed and locked?
In Ontario, what is the role of the TSSA Elevating Devices Code Adoption Document (CAD)?
Under CSA Z185, what is the maximum clearance allowed between the hoist car sill and the landing sill?
According to CSA Z256, what is the minimum height required for landing gates on a material hoist?
What distinguishes the ANSI A10.22 standard from the CSA Z185 standard?
Under CSA Z185, what is the maximum rated speed allowed for a construction personnel hoist that is not equipped with a special high-speed drive and monitoring system?
According to CSA Z185, how often must a full load safety drop test be conducted on a personnel hoist?
When a material hoist is configured under CSA Z256, what safety device must be active on the car to arrest it if the hoisting rope breaks?
According to the Ontario CAD amendments, what is the safety factor required for the suspension wire ropes on a personnel hoist?
Under CSA Z185, what is the maximum allowable horizontal deflection of the hoist mast under full rated load and maximum wind conditions?
According to CSA Z185, when the hoist car is at its maximum upward travel, what is the minimum required distance between the top of the car roof structure and the underside of the cathead sheaves?
If a conflict arises between a clause in the national CSA Z185 safety standard and a clause in the Ontario TSSA Code Adoption Document (CAD), which rule takes precedence?
During a visual inspection of a hoist wire rope, what is the primary indicator that the rope must be immediately removed from service?
Rigging And Hoisting
What does the designation 'WLL' stamped on a rigging shackle represent?
Which of the following is the correct safety factor for general rigging hardware (such as shackles, hooks, and links) used in construction hoisting?
When using a screw-pin shackle for a lift, what safety precaution must be taken with the pin?
What is the primary purpose of sheave grooves on a hoisting system?
According to ASME B30.30 and CSA standards, what is the maximum allowable diameter reduction for a 19 mm (3/4 inch) wire rope before it must be replaced?
A steel mast section weighs 450 kg. If you are lifting a bundle of 4 mast sections using a two-leg sling, what is the total static weight of the load?
When lifting a load using a two-leg bridle sling, what happens to the tension in each sling leg as the horizontal angle of the sling decreases (i.e., the legs get closer to the load)?
Using the standard sling angle factor, if a load of 2,000 lbs is lifted with a two-leg sling at a 45-degree horizontal angle, what is the tension in each sling leg? (Sling factor for 45 degrees is 1.414)
When inspecting a running wire rope, what is the maximum number of broken wires allowed in one rope lay before the rope must be discarded?
What is the correct orientation of a U-bolt wire rope clip (Crosby clip) when securing a dead end?
Loading more…