What is the primary purpose of a blower door test in residential buildings?
Blower Door Testing
Question · Easy
At what standard test pressure is a single-point blower door test typically conducted?
Which ASTM standard governs the procedure for conducting blower door tests?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Before setting up a blower door, which of the following preparatory steps must be completed?
What does CFM50 represent in blower door testing?
A blower door test on a 2,000 sq ft home with 8-foot ceilings yields a CFM50 reading of 2,400. What is the ACH50?
Infiltration Calculations
What is the typical division factor used to estimate natural air changes per hour (ACHnat) from ACH50?
During a blower door test in depressurization mode, the fan is configured to:
Which environmental condition can most significantly affect the accuracy of a blower door test?
What is the purpose of a baseline pressure reading taken before a blower door test?
In a multipoint blower door test, measurements are typically taken at which range of pressures?
Question · Hard
In the blower door leakage equation Q = C × ΔP^n, what does the exponent 'n' represent?
What should be done with the fireplace damper before conducting a blower door test?
Which component of the blower door system measures the pressure difference between inside and outside?
Equipment Calibration
What is the function of flow rings (or range plates) on a blower door fan?
A blower door is installed in the front door frame. During depressurization testing, where should the outdoor reference pressure tube be placed?
What is the primary purpose of duct leakage testing in residential buildings?
Duct Leakage Testing
Which ASTM standard governs the procedure for duct leakage testing?
What equipment is specifically designed for pressurizing duct systems to measure duct leakage?
When setting up a duct blaster for total duct leakage testing, what must be done to all supply and return registers?
What is the standard test pressure for duct leakage testing?
What is the difference between 'total duct leakage' and 'duct leakage to outside'?
How is 'duct leakage to outside' measured using the subtraction method?
During a duct leakage to outside test using the subtraction method, what equipment must be operating simultaneously?
A duct leakage test yields a total duct leakage of 180 CFM25 and duct leakage to outside of 120 CFM25. How much duct leakage is occurring to conditioned space?
According to the IECC, what is a common maximum allowable total duct leakage rate for new construction?
What is a pressure pan test used for?
Pressure Diagnostics
During a pressure pan test, the house is depressurized to -50 Pa with a blower door. A pressure pan reading of 0 Pa at a supply register indicates:
During a pressure pan test at -50 Pa house pressure, a register in the living room reads 35 Pa. What does this indicate?
What are the three main driving forces of air leakage in buildings?
Air Leakage Principles
The stack effect in a building causes air to:
The neutral pressure plane in a building experiencing stack effect is the level where:
Which area of a typical home is usually the largest source of air leakage?
What is the relationship between air leakage and moisture problems in buildings?
A building has a conditioned volume of 12,000 cubic feet and a CFM50 of 1,200. Using an N-factor of 20, what is the estimated natural infiltration rate (CFMnat)?
How is Equivalent Leakage Area (ELA) different from CFM50?
What does ACH50 stand for, and how is it calculated?
A 1,500 sq ft single-story home with 8-foot ceilings has an ACH50 of 5. What is the CFM50?
What does the Building Tightness Limit (BTL) represent?
Ventilation Safety
According to ASHRAE Standard 62.2, the minimum whole-building ventilation rate for a residence is based on:
Using the ASHRAE 62.2 formula, what is the minimum continuous ventilation rate for a 2,000 sq ft home with 3 bedrooms?
What is the infiltration credit in ASHRAE 62.2, and how does it affect the required mechanical ventilation rate?
Why is combustion safety testing important in conjunction with air leakage testing?
What is the Combustion Appliance Zone (CAZ), and why is it important in air leakage work?
What is the purpose of zonal pressure diagnostics?
During a blower door test at -50 Pa, a zonal pressure reading of the attic shows 48 Pa with respect to the house. What does this indicate?
During a blower door test at -50 Pa, a zonal pressure measurement of an attached garage shows 10 Pa with respect to the house. What does this suggest?
Loading more…