Which transport mechanism moves solutes across a dialysis membrane down a concentration gradient without requiring pressure?
Dialysis Principles
Question · Easy
Osmosis in dialysis refers to the movement of:
Kind of access made with a man-made tube that joins an artery to a vein when a fistula is not possible.
Vascular access
Guess the Term
Chapter 1: Introduction & Foundation
1.1 About the BONENT CHT Exam
Study guide
Ultrafiltration during hemodialysis is achieved by:
Read the clue and guess the term in 6 tries.
Game
Convective transport in hemodialysis occurs when:
Ideal ___ weight is the weight a patient has when no extra fluid remains.
Fluid management
A high-flux dialyzer is characterized by:
Dialyzer
The blood path in a modern hollow-fiber dialyzer runs:
Painful muscle tightening during dialysis that can result when fluid is removed too quickly.
Complications
1.2 Renal Anatomy & Pathophysiology Basics
The minimum Urea Reduction Ratio (URR) recommended by KDOQI for thrice-weekly hemodialysis is:
Adequacy
Swap tiles to line up three of the same term.
Term Match
The target single-pool Kt/V (spKt/V) for a thrice-weekly hemodialysis patient per KDOQI guidelines is at least:
Blockage made of blood that can stop a vascular access from working.
The most commonly used anticoagulant in routine hemodialysis is:
Anticoagulation
Per the KDOQI Fistula First initiative, the preferred permanent vascular access for hemodialysis is:
Vascular Access
Swelling caused when damaged kidneys cannot remove extra fluid and salt.
Chapter 2: Vascular Access & Cannulation
2.1 Types of Vascular Access (AVF, AVG, CVC)
Which cannulation technique uses the same needle insertion sites each session, forming a track or buttonhole through scar tissue?
Flip two cards at a time to find matching terms.
Term Pairs
The primary purpose of priming the extracorporeal blood circuit before connecting the patient is to:
Machine Setup
Condition in which blood has fewer red cells or less hemoglobin than normal.
The standard dialysate bicarbonate concentration used in chronic hemodialysis to correct metabolic acidosis is approximately:
Dialysate
The water treatment component that removes the highest percentage of dissolved ions and organics for dialysate production is:
Water Treatment
Condition whose patients may be treated with dialysis or a transplant and for which Medicare certifies dialysis facilities.
Patient assessment
2.2 Cannulation Techniques & Aseptic Site Prep
CDC hemodialysis precautions require that hepatitis B surface antigen (HBsAg)-positive patients dialyze:
Infection Control
Find five hidden terms in a grid of letters.
Term Search
Blood urea nitrogen (BUN) in dialysis patients primarily reflects:
Ckd Labs
Lab value for a protein-breakdown waste, drawn before and after a treatment so the reduction ratio can show how efficient dialysis was.
The most common intradialytic complication in hemodialysis is:
Dry weight in a hemodialysis patient is defined as the post-dialysis weight at which the patient is:
Dry Weight
Mineral in foods and drinks that dialysis patients may need to limit.
Patient education
2.3 Access Assessment, Maturation & Complications
A hemodialysis patient should be instructed to limit dietary potassium primarily because ESRD patients are at risk for:
Patient Education
Nursing & Healthcare Exam Prep Podcast
Listen on Spotify
Podcast
During a cardiac arrest in the dialysis unit, the technician's first action after confirming unresponsiveness and calling for help should be:
Bls Osha
Gloves, gown, mask and eye wear worn during dialysis start and end to block contact with blood.
Infection control
The primary purpose of carbon filtration in the dialysis water treatment system is to remove:
When the venous pressure alarm activates during hemodialysis (pressure higher than set limit), the technician should first suspect:
Blood test result that, when positive, requires the patient to be isolated from other dialysis patients.
Chapter 3: Intradialytic Care & Complication Management
3.1 Pre-Dialysis Assessment & Dry Weight Determination
A pre-dialysis serum potassium of 6.8 mEq/L in a chronic HD patient is best classified as:
The typical dialysate sodium concentration used in hemodialysis is:
Needles, scalpels, and broken glass that can penetrate skin and must be discarded immediately or as soon as feasible after use.
When accessing a tunneled hemodialysis catheter, the technician must use which level of infection prevention precautions?
Loading more…