How many BOMI courses are required to earn the Systems Maintenance Technician (SMT) designation?
Designation Requirements
Question · Easy
GFCI inspection
Short
What is the entry-level experience requirement for the SMT designation?
How many degrees Fahrenheit must one pound of water be heated to gain one BTU?
Applied Math
Real Estate Exam Prep Podcast
Listen on Spotify
Podcast
One ton of refrigeration capacity equals how many BTU per hour?
Refrigeration
In a basic vapor-compression refrigeration cycle, where does refrigerant absorb heat from the conditioned space?
Never vent refrigerant
Refrigerant R-22 (HCFC) is being phased out under what international agreement?
Question · Medium
An EPA Section 608 Type I technician certification authorizes work on:
Which gauge port on a refrigeration manifold connects to the high-pressure side of the system?
Cooling tower fill primarily increases:
Spin the wheel: name the extinguisher
Boilers used for space heating in commercial buildings most commonly operate at:
Boilers
A pressure relief valve on a boiler is designed to:
What is the most common heat-transfer fluid in commercial heating systems?
What is the function of a steam trap?
What a Safety Data Sheet tells you
What is the purpose of feedwater treatment in boilers?
Water Treatment
Dissolved oxygen in boiler feedwater is most effectively removed by:
A cooling tower blowdown valve controls:
The most effective Legionella growth zone for hot water systems is approximately:
A potable water backflow preventer protects:
Plumbing
What is the unit of measure for electrical resistance?
Electrical Systems
Ohm's Law states that:
A 120-volt circuit draws 10 amperes. The power consumed is:
GFCI receptacles are required by code in:
Lockout/tagout (LOTO) under OSHA 1910.147 requires:
Which type of light source has the highest efficacy (lumens per watt) for general illumination in commercial buildings today?
What is the typical voltage used for branch lighting circuits in commercial buildings?
What is the most common HVAC air filter rating used in basic commercial buildings?
Building Systems
Routine HVAC filter changes are most commonly scheduled:
Belt-driven HVAC fans require what routine maintenance?
What is the primary purpose of an HVAC chilled water pump?
Air handling unit (AHU) preventive maintenance commonly includes:
What does the abbreviation PSI refer to?
Atmospheric pressure at sea level is approximately:
A pump produces 30 psi of pressure. This corresponds to approximately how many feet of water head?
A 200-gallon water heater is heated from 50 degrees F to 130 degrees F. Approximately how many BTU are required (water weighs 8.34 lb/gal)?
Boilers must be inspected periodically by jurisdiction-authorized inspectors. A typical inspection frequency for power boilers is:
What is the function of a flow switch in a boiler or chiller system?
What is the purpose of an expansion tank in a closed hot water heating system?
What does the abbreviation NEC stand for in electrical work?
In a panelboard, breakers protect:
Three-phase commercial electrical service typically uses what conductor configuration?
A common cause of fluorescent fixture failure that is not the lamp itself is:
What does the term lumens describe?
In an HVAC chilled water system, supply water temperature is typically:
Loading more…