The Systems Maintenance Administrator (SMA) designation requires completion of all five SMT courses plus how many additional BOMI courses?
Designation Requirements
Question · Easy
Never enter a tank before testing the air
Short
How many years of verifiable stationary engineer or equivalent experience does BOMI require for the SMA designation?
In a vapor-compression refrigeration cycle, the component that increases refrigerant pressure and temperature is the:
Refrigeration
Real Estate Exam Prep Podcast
Listen on Spotify
Podcast
Which refrigerant property is most relevant to ozone depletion potential (ODP)?
Question · Medium
Under EPA Section 608, a Type II technician certification authorizes service of:
What is the standard SI unit for refrigeration capacity used in U.S. commercial HVAC?
A chiller has a coefficient of performance (COP) of 6.0. What is its EER (energy efficiency ratio)?
Question · Hard
In a low-pressure centrifugal chiller using R-123, the typical operating evaporator pressure is:
Cooling tower approach is best defined as:
A cooling tower's blowdown rate is set to:
Water Treatment
Which chemical is commonly added to cooling tower water as a biocide?
ASHRAE Standard 188 requires what for at-risk building water systems?
In a steam boiler, what is the primary function of a feedwater pump?
Boilers
Which safety device protects a steam boiler from overpressure conditions?
Boiler efficiency is most directly improved by:
In a hot water heating loop, dead-end branches can:
Plumbing
A typical domestic hot water system temperature setpoint at the heater is:
What is the purpose of a backflow preventer in a building water system?
A water hammer in piping occurs when:
In an electrical system, the unit of measure for real power consumed by equipment is:
Electrical Systems
A motor operating at 480 volts, 3-phase, draws 60 amps and has a power factor of 0.85. Real power is approximately:
Power factor correction in commercial buildings is achieved by adding:
OSHA's lockout/tagout standard requires which sequence?
An arc flash hazard is best mitigated by:
Which lighting metric measures the perceived color quality of light from a source?
A typical office's target illuminance per IES recommendations is:
Variable air volume (VAV) systems modulate which parameter to match space load?
Building Systems
An economizer cycle in an HVAC system uses:
A direct digital control (DDC) system uses what to control mechanical equipment?
Building Technology
In a PID control loop, the integral term primarily addresses:
A typical commercial building's outdoor air ventilation rate is established by:
OSHA's permissible exposure limit (PEL) for carbon monoxide is:
Environmental Health Safety
In stationary engineering, the term turndown ratio describes a boiler's:
What is the most common reason for a boiler low-water cutoff to trip?
Stationary engineers calculate the heat required to raise 1 pound of water 1 degree F as:
Applied Math
A 500-gallon hot water tank is heated from 60 degrees F to 140 degrees F. Approximately how many BTU are required (water weighs ~8.34 lb/gal)?
The latent heat of vaporization of water at atmospheric pressure is approximately:
Steam quality in a boiler refers to:
Pump head in feet of water can be converted to pressure in psi by:
Pump affinity laws state that pump flow varies with what relative to speed?
In an electrical system, a ground fault circuit interrupter (GFCI) protects against:
An AFCI device installed on residential circuits primarily protects against:
What is the most efficient lighting technology widely used in modern commercial buildings?
In a building automation system, a trend log records:
A pneumatic control system uses what medium to operate dampers and valves?
Indoor relative humidity is best controlled within what range for occupant comfort and minimal condensation/mold risk?
Loading more…