In a month with 720 hours, a 150 m² open-plan office has an average internal heat gain density of q_int = 6 W/m² from occupants, PCs, and lighting. If total monthly building heat losses (transmission + ventilation) are Q_ht = 3,200 kWh and the gain utilization factor is η_H,gn = 0.90, what is the net space heating energy demand (Q_H,nd) for the month (assuming solar gains are 500 kWh)?
- A2,552 kWh
- B2,052 kWh
- C2,167 kWh
- D3,050 kWh