A 24 V DC source is connected across an 8 Ω resistor. What is the current?
Electrical Circuits
Question · Easy
At a circuit node, 4 A and 2 A enter and 3 A leaves. What current must leave through the remaining branch to satisfy KCL?
An 18 V source feeds 3 Ω in series with 6 Ω. What is the voltage across the 6 Ω resistor?
Government Exam Prep Podcast
Listen on Spotify
Podcast
A 6 Ω resistor is in parallel with a 3 Ω resistor. What is the equivalent resistance?
Two voltage sources share a mesh: 10 V and an opposing 5 V with 2 Ω and 3 Ω in series around the loop. What is the mesh current?
Question · Medium
Maximum power is transferred to a load when the load resistance equals:
A 12 V source has 4 Ω in series, then a 12 Ω shunt to ground. What are VTh and RTh at the shunt terminals (load removed)?
Question · Hard
For the same network (VTh = 9 V, RTh = 3 Ω), the Norton equivalent current is:
A Thevenin source VTh = 12 V, RTh = 4 Ω feeds a matched load. What is the maximum power delivered to the load?
A sinusoidal voltage is v(t) = 170 sin(ωt) V. What is its RMS value (nearest volt)?
A series RLC circuit has L = 10 mH and C = 100 µF. The resonant frequency is nearest to:
A balanced three-phase load draws IL = 10 A at VL = 400 V and lagging power factor 0.8. The three-phase real power is nearest to:
Each branch of a balanced delta is 9 Ω. The equivalent wye resistance per phase is:
Faraday’s law of electromagnetic induction states that the induced EMF in a coil is equal to:
Electrical Machines Transformers
An ideal transformer is 11 kV / 440 V with 1100 primary turns. The secondary turns are:
A 4-pole synchronous machine is supplied at 50 Hz. Its synchronous speed is:
A 10 kVA, 200/400 V single-phase transformer has rated currents of:
A 50 Hz, 4-pole induction motor runs at 1440 rpm. The slip is:
A DC motor has V = 220 V, Ia = 20 A, and Ra = 0.5 Ω. The back EMF is:
The RMS induced EMF of a single-phase transformer winding is E = 4.44 f N Φm. For f = 50 Hz, N = 200, and Φm = 0.05 Wb, E is:
A lap-wound DC generator has Φ = 0.02 Wb, Z = 400, N = 1200 rpm, P = 4, and A = 4. The generated EMF is:
A transformer delivering 40 kW of output has 2 kW of total losses. Its efficiency is nearest to:
A transformer secondary is 220 V on no load and 210 V on full load at a given power factor. Voltage regulation is nearest to:
In a transformer, the open-circuit (no-load) test is performed to determine:
For a three-phase induction motor, breakdown (maximum) torque occurs at a slip approximately equal to:
A squirrel-cage induction motor is commonly started by a star–delta starter in order to:
A delta–star (Dy) three-phase transformer connection is commonly chosen for distribution because it:
An over-excited synchronous motor operating on a constant-voltage bus behaves as:
Armature reaction in a DC generator at unity-power-factor (non-inductive) load is predominantly:
A single-line diagram of a power system shows:
Power System
A machine impedance is 0.10 pu on a 50 MVA base. On a 100 MVA system base the same impedance is:
A short transmission line is modelled by:
SF6 circuit breakers extinguish the arc primarily because sulphur hexafluoride:
An IDMT overcurrent relay is characterised by:
For a bolted single line-to-ground fault at a bus, the sequence networks are:
A mho distance relay has a circular characteristic in the R–X plane that:
Among FACTS devices, a STATCOM is best described as:
The equal-area criterion for a one-machine–infinite-bus system compares:
A two-terminal HVDC link typically uses converters that, in classical current-source schemes, are:
Current chopping in a circuit breaker is a concern mainly when interrupting:
Percentage differential protection of a transformer must include current matching and often harmonic restraint because:
A UPFC (unified power flow controller) can, within ratings, simultaneously control:
Load factor of a plant is defined as:
Power Plant Engineering
If a system’s average load is 40 MW and its peak load is 80 MW, the load factor is:
A generating station has 100 MW installed capacity and 40 MW average output over a year. Its capacity (plant) factor is:
Base-load plants are generally those with:
Diversity factor is: