Which nationally recognised unit of competency maps to the Advanced Rigging (RA) high risk work licence class?
Planning Advanced Rigging
Question · Medium
What is the mandatory prerequisite before enrolling in Advanced Rigging (RA) training and assessment?
Under the SafeWork NSW hierarchy of high risk work licensing, which classes does an RA licence also authorise?
Question · Hard
According to SafeWork NSW, which tasks are RA-specific additions beyond Intermediate Rigging (RI) scope?
Which document is legally required for high-risk construction work such as advanced rigging on an Australian construction site?
After receiving a Notice of Satisfactory Assessment (NSA) for RA, how long do you typically have to apply for the licence?
Question · Easy
How long is an Australian high risk work licence generally valid before renewal is required?
If an RA licence expires and is not renewed within 12 months, what is generally required?
Under the WHS Act, what is a licenced advanced rigger's primary personal duty of care?
What is the first control measure a rigger should consider in the hierarchy of control when planning a complex lift?
Before starting advanced rigging work, what must be done with lifting gear that has a missing or illegible WLL tag?
Which communication methods are typically required to be maintained during advanced plant erection such as flying-fox or gin-pole operations?
Who assesses competence for an RA high risk work licence in NSW?
What is the SafeWork NSW government fee for a new high risk work licence class (2026–27 schedule)?
Minimum age to apply for an Australian high risk work licence including RA is:
What best describes a gin pole used in advanced rigging?
Gin Poles And Shear Legs
What is the minimum recommended number and layout of guy ropes for a gin pole?
If a gin pole uses five guy ropes, what is the typical purpose of the additional (fifth) guy?
What is the maximum allowable lean for a gin pole relative to pole length?
What is the minimum recommended distance from the heel (base) of a gin pole to the back-guy anchor?
A gin pole is 10 m long. What is the maximum allowable lean?
A gin pole is 9 m long. What is the minimum distance from the heel to the back-guy anchor?
How is Total Head Load (THL) calculated for a gin pole lift?
For a powered gin-pole lift, compression on the pole is estimated as:
For a hand-powered gin-pole lift, compression on the pole is estimated as:
THL for a powered gin-pole lift is 6.2 t. What is the estimated compression on the pole?
For a powered gin-pole lift, tension in the back guy is estimated as:
Powered-lift gin-pole compression is 6975 kg. Approximate back-guy tension is:
What best describes a shear leg used in advanced rigging?
For shear legs, the distance from the heels to the back-guy anchorage should not be less than:
What is the maximum forward lean commonly taught for shear legs, measured from the vertical?
For shear legs, the angle of tilt must not exceed approximately:
Why must heel tackle on shear legs be adequately secured?
Wire ropes used as gin-pole guys or stays should typically be no less than which construction?
What should be done where guy or stay ropes run over sharp edges or around columns?
If more than one back guy is used on a gin pole, what must be done?
A gin pole has limited forward or sideways movement. What does this imply for lift planning?
Stays and guys on gin poles should preferably have what at the top end?
A gin pole lifts a 5 t load with 1.5 t in the lead rope. What is THL?
Which statement about tripods in advanced rigging is most accurate?
What is a flying fox in advanced rigging terms?
Flying Foxes And Cableways
How does a cableway/span rope differ in concept from a flying fox?
What is the minimum allowable sag commonly used for a flying-fox/cableway main cable?
For a span of 18 m at minimum allowable sag, what is S?
Which formula calculates main-cable tension for a flying fox/cableway?
At the minimum allowable sag (S = L/20), tension simplifies to approximately:
Load to lift is 350 kg and lifting gear is 60 kg on an 18 m span at S = 0.9 m. Approximate main-cable tension is:
Using Tension = 2050 kg, what is the estimated minimum FSWR diameter from diameter = √(Tension ÷ 8)?
Loading more…