In the basic vapour-compression refrigeration cycle, which component is responsible for raising the pressure and temperature of the refrigerant vapour?
Vapour Compression Cycle
Question · Easy
Where in the vapour-compression cycle does the refrigerant absorb heat from the conditioned space or product?
The two phase changes that occur in a vapour-compression system are best described as:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Superheat in a refrigeration system is defined as:
Question · Medium
Subcooling at the condenser outlet is important because it:
On a pressure-enthalpy (P-h) diagram, the throttling process through the expansion valve is represented by a line that is:
Question · Hard
The coefficient of performance (COP) of a refrigeration system in cooling mode is calculated as:
The 'refrigerating effect' of a system refers to the:
Latent heat, as it applies to refrigeration, is the heat that:
In a reverse-cycle (heat pump) air conditioner, which component changes the direction of refrigerant flow to switch between heating and cooling?
If a system has a very high compression ratio (condensing pressure much higher than evaporating pressure), the most likely effect is:
On a pressure-temperature (PT) chart, for a given refrigerant the saturation pressure read against a temperature tells the technician:
Flash gas in the liquid line is caused by:
Which statement about the high side and low side of a running system is correct?
A liquid receiver is fitted in a refrigeration system mainly to:
System Components
The main job of a thermostatic expansion valve (TX/TEV) is to:
A filter drier is installed in the liquid line primarily to:
A suction accumulator is fitted to:
Which type of compressor uses two interleaving spiral elements, one fixed and one orbiting, to compress refrigerant?
A capillary tube as a metering device works by:
An oil separator on the compressor discharge line is used to:
The sight glass with a moisture indicator in a liquid line allows a technician to check for:
In an air-cooled condenser, heat is rejected from the refrigerant to:
A high-pressure cut-out (HP) switch protects the system by:
Electrical And Controls
What is the primary function of a contactor in an air-conditioning control circuit?
Under the Australian MEN system, an electrical installation's neutral is connected to earth at:
A potential relay used to start a single-phase PSC or CSR compressor motor removes the start capacitor from the circuit by:
A run capacitor in a single-phase PSC compressor or fan motor is connected:
The three motor winding terminals on a hermetic compressor are commonly labelled:
A residual current device (RCD) protects people against electric shock by:
An inverter-driven (variable-speed) air conditioner saves energy mainly because it:
Before working on the electrical components of an air conditioner, the safe isolation procedure requires you to:
A defrost termination thermostat on a heat-pump outdoor coil is used to:
A licence issued by the Australian Refrigeration Council (ARC) under the ARCtick scheme is legally required to:
Refrigerants And Arctick
Venting (deliberately releasing) fluorocarbon refrigerant to atmosphere during service work in Australia is:
Under the refrigerant safety classification system (AS/NZS ISO 817 / ASHRAE 34), the designation 'A2L' indicates a refrigerant that is:
Why are HCFCs such as R22 being phased out in Australia?
A refrigerant's Global Warming Potential (GWP) is a measure of:
Recovered refrigerant that is contaminated or no longer fit for reuse should be:
When charging a blend (zeotropic) refrigerant such as R407C, it should be drawn from the cylinder as a:
When installing equipment using a flammable A2L refrigerant such as R32, the technician must pay particular attention to:
A refrigerant cylinder being filled with recovered refrigerant must never be filled beyond its safe fill limit because:
Compared with natural gas, LPG (used in some absorption or transport refrigeration contexts) and many hydrocarbon refrigerants are:
Dry-bulb temperature measured with an ordinary thermometer indicates:
Psychrometrics
Relative humidity (RH) is defined as:
Dew point temperature is the temperature at which:
An air-conditioning coil dehumidifies air by:
Loading more…