Calculate the Ug-value per EN 673 for a double-glazed IGU (4-16-4) given: external surface conductance h_e = 23.0 W/(m²·K), internal surface conductance h_i = 7.7 W/(m²·K), thermal conductivity of soda-lime glass lambda = 1.0 W/(m·K), and cavity gas thermal conductance h_s = 1.34 W/(m²·K).
- AUg = 1.08 W/(m²·K) (rounded to 1.1 W/(m²·K))
- BUg = 0.55 W/(m²·K)
- CUg = 1.65 W/(m²·K)
- DUg = 2.80 W/(m²·K)