Which laser line is commonly used to excite FITC in conventional flow cytometry?
Flow Instrumentation Optics
Question · Easy
Forward scatter (FSC) signal is most closely correlated with which cellular property?
Detector that amplifies weak light through a series of dynodes.
Instrumentation
Guess the Term
Chapter 1: Flow Cytometry Instrumentation & Biophysics
1.1 Fluidic Systems: Hydrodynamic Focusing, Acoustic Focusing, Laminar Flow & Sheath Dynamics
Study guide
Side scatter (SSC) is primarily a measure of:
Read the clue and guess the term in 6 tries.
Game
Hydrodynamic focusing in a flow cytometer is achieved by:
Question · Medium
Signal proportional to cell size, measured just off the beam axis.
Which detector type is most commonly used for fluorescence detection in conventional flow cytometers?
A bandpass filter labeled 530/30 transmits light:
Signal proportional to internal granularity, collected at about 90 degrees to the beam.
1.2 Laser Physics, Light Sources & Beam Shaping Optics
The 405 nm violet laser is used to excite which fluorochromes?
Swap tiles to line up three of the same term.
Term Match
How does a full-spectrum flow cytometer assign measured fluorescence to individual fluorochromes?
Flow Stem Cell Enumeration Specialty
Single-wavelength source of a focused, narrow beam, such as the 488 nm argon-ion unit common in cytometers because it excites several fluorochromes.
Where does optical interrogation occur in a classic jet-in-air sorter?
On a sort, the drop delay determines:
Question · Hard
Control tube that contains all labeled antibodies in a multicolor experiment except the single reagent being measured.
Experiment design
1.3 Optical Layout: Dichroic Mirrors, Bandpass Filters & Spatial Separation
A cytometer has 405, 561, 633, and 355 nm lasers. Which is the best choice for exciting R-phycoerythrin (R-PE)?
Flip two cards at a time to find matching terms.
Term Pairs
On a cytometer with spatially separated 488 nm and 561 nm interrogation points, what panel design can reduce FITC–PE spillover?
Flow Sample Prep Antibodies Compensation
Label whose absorption maximum is near the 488 nm argon line and whose emission peaks at 530 nm.
Both size-reference beads and a control lymphocyte sample shift to lower FSC at unchanged settings. What should be checked first?
What limits the use of an FSC gate alone to exclude dead cells?
Water-soluble algal pigment with absorption near 652 nm and emission near 658 nm, used as a far-red label.
1.4 Photo Detectors: PMTs, APDs, Silicon Photomultipliers & Spectral Arrays
Which dye pair is designed for a 355 nm UV laser?
Find five hidden terms in a grid of letters.
Term Search
Acoustic focusing (e.g., Attune NxT) provides what advantage over hydrodynamic focusing?
Collection of antibody-fluorochrome combinations, often across several tubes, chosen to identify cell populations.
A long-pass dichroic mirror at 600 nm:
What changes when the acquisition threshold on the FSC channel is raised?
Optimal antibody dilution found by testing a series of decreasing concentrations.
1.5 Signal Processing, Pulse Geometry & Preamplifiers
Pulse processing in flow cytometry produces three primary parameters from each detector:
Nursing & Healthcare Exam Prep Podcast
Listen on Spotify
Podcast
Why is a 488 nm laser preferred over a 532 nm laser for FITC excitation?
Four-parameter flow method for counting CD34-positive cells in peripheral blood and apheresis products.
Applications
A conventional cytometer detects both BV421 and Pacific Blue in the same 450/50 channel without separate spectral measurements. What should the panel designer do?
Compensation in flow cytometry corrects for:
Very small number of cancer cells remaining during or after treatment, found only by methods able to detect one cancer cell among a million normal cells.
1.6 Analog-to-Digital Conversion (ADC) & Dynamic Range
A fluorescence-minus-one (FMO) control is used to:
A clinical flow lab has verified EDTA and sodium heparin for its blood immunophenotyping panel. Which specimen can be accepted under that collection protocol?
Cancer seed shed from a primary growth into the bloodstream.
Tandem dyes such as PE-Cy7 and APC-Cy7 are particularly susceptible to: