Free Journeyman Plumber Practice Test by State: 2026 Guide
Video
Under the UPC as adopted in Alaska, what is the minimum size drain pipe required for a water closet?
Drainage Systems
Question · Easy
How to Become a Plumber in 2026: License, Salary by State & Career Path
Complete 2026 guide to becoming a plumber. Covers apprenticeship requirements, journeyman and master licensing, BLS May 2025 median pay of $63,800, specializations, and career advancement. Free plumber exam prep included.
Blog
Branch interval
Administration and General Regulations
Flashcard
According to the UPC as enforced by the Alaska Department of Labor, what is the minimum slope for a 4-inch horizontal drainage pipe?
Chapter 1: Administration, Code Enforcement, & Safety
1.1 Administration, Permits, and Inspections
Study guide
Under the UPC as adopted in Alaska, what is the DFU (Drainage Fixture Unit) value for a residential lavatory?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Where does the building drain end and the building sewer begin?
Per the UPC as enforced in Alaska, what is the minimum depth of a fixture trap seal?
Find 45 plumber practice routes across 44 states and DC, confirm your actual credential and references, and work through source-bounded code and trade-math examples.
According to the UPC as adopted in Alaska, what is the minimum vent pipe size for an individual fixture with a 2-inch trap?
Venting
Vent stack vs. stack vent
Under the UPC as enforced in Alaska, what is the minimum vent termination height above a roof surface?
Question · Medium
1.2 General Regulations & Building Integrity
Per the UPC as adopted in Alaska, what type of backflow preventer is required for a high-hazard cross-connection?
Water Supply
Flood level rim vs. critical level
According to the UPC as enforced in Alaska, what is the maximum hot water temperature permitted at fixtures for bathing and showering?
Under the UPC as adopted in Alaska, what is the minimum water supply pipe size for a single-family dwelling?
What do you read off an isometric (riser) drawing on this exam?
Per the UPC as enforced in Alaska, what is the maximum static water pressure allowed in a building's water distribution system?
1.3 Material Standards & Piping Joining Methods
According to the UPC as adopted in Alaska, what is the minimum cleanout interval for horizontal drainage piping 4 inches and smaller?
Developed length
Under the UPC as enforced in Alaska, which piping material is approved for underground water service?
Materials Joints
Per the UPC as adopted in Alaska, what is the minimum clearance in front of a water closet to the nearest obstruction?
Fixtures Appliances
Architect's scale: what does 1/4 inch = 1 foot-0 inches mean when you measure a plan?
According to the UPC as enforced in Alaska, what is the required test for a new DWV system?
Code Administration
1.4 Plumbing Math & Water Calculations
Under the UPC as adopted in Alaska, what is the minimum size building sewer?
IPC 312.2 - drainage and vent WATER test
Per the UPC as enforced in Alaska, what special consideration applies to plumbing in buildings with permafrost conditions?
According to the UPC as adopted in Alaska, what is the minimum size trap for a residential bathtub?
IPC 312.3 - drainage and vent AIR test
Under the UPC as enforced in Alaska, what is the minimum water supply pipe size to a kitchen sink?
1.5 Isometric Drawings & Blueprint Reading
Per the UPC as adopted in Alaska, what is the maximum number of DFUs permitted on a 3-inch horizontal branch?
Question · Hard
IPC 312.5 - water supply system test
According to the UPC as enforced in Alaska, what is the required gas piping test pressure?
Gas Piping
Under the UPC as adopted in Alaska, what is the minimum size wet vent that can serve a bathroom group including a water closet?
IPC 312.4 - drainage and vent FINAL test (smoke test)
Per the UPC as enforced in Alaska, when must a grease interceptor be installed?
Special Systems
Chapter 2: Plumbing Fixtures, Appliances, & Water Heaters
Plumbing Fixtures & Minimum Standards
According to the UPC as adopted in Alaska, what is the minimum pipe burial depth for a water service in areas subject to freezing?
IPC 312.9 - shower liner test
Under the UPC as enforced in Alaska, what type of fitting is prohibited in horizontal drainage piping?
Per the UPC as adopted in Alaska, what is the minimum T&P relief valve discharge pipe size?
What does 'lead free' mean for potable water piping?
Loading more…