Which organization administers the Certified Professional Electrologist (CPE) examination?
Professional Practice
Question · Easy
Needlestick at 10:02
Short
Through which testing vendor is the CPE examination delivered at standardized computer-based testing centers?
How many continuing-education contact hours must a CPE complete to maintain the credential through one five-year cycle?
Question · Medium
In what stage of the hair growth cycle is electrolysis MOST effective at producing permanent destruction of the follicle?
Skin Anatomy And Hair Cycle
Which structure at the base of the follicle supplies nutrients to the developing hair and is the primary target of permanent hair removal?
What the hep B vaccine costs you at work
Which of the following best describes the difference between hirsutism and hypertrichosis?
Question · Hard
What type of electrical current is used in the galvanic (chemical) method of electrolysis?
Galvanic Method
In galvanic electrolysis the active chemical that destroys follicular tissue is produced at the probe and is commonly called:
Which method of electrolysis uses high-frequency alternating current at approximately 13.56 MHz to coagulate follicular tissue with heat?
Thermolysis Method
Blend electrolysis combines which two modalities to leverage the benefits of each?
Blend Method
What is the single greatest advantage of the blend method over straight thermolysis?
What is the recommended steam-autoclave standard cycle for sterilizing reusable electrology instruments?
Infection Control And Sterilization
Which OSHA standard governs occupational exposure to bloodborne pathogens in the electrology workplace?
Laws And Ethics
How does the FDA classify electrology epilation devices?
A client mentions she has a cardiac pacemaker. What is the appropriate action regarding electrolysis treatment?
Side Effects And Contraindications
Which skin reaction immediately following treatment is characterized by transient redness around the follicle and is considered a normal response?
Hyperpigmentation following electrolysis is most commonly the result of:
Which type of probe is generally recommended for clients with a history of nickel sensitivity?
Equipment And Needles
The primary purpose of an insulated probe is to:
What is the proper handling of a single-use, pre-sterilized disposable probe?
Which chemical sterilant is acceptable for high-level disinfection of heat-sensitive electrology instruments when used for the manufacturer-specified contact time?
Universal Precautions assume that:
How long does a normal anagen (active growth) phase typically last for scalp hair?
Which sensory observation can help the electrologist verify probe insertion depth has reached the bulb area?
When inserting a probe, the electrologist should follow:
In galvanic electrolysis the client typically holds the:
What does the term 'permanent hair removal' as used in U.S. regulation refer to?
Which of the following is an absolute contraindication for electrolysis without medical clearance?
Why is poorly controlled diabetes a relative contraindication for electrolysis?
The pilosebaceous unit consists of:
Vellus hair differs from terminal hair primarily in that vellus is:
Which of the following describes catagen phase?
Telogen phase is best described as:
Why is treating telogen hairs less effective than treating anagen hairs?
The 'units of lye' concept in galvanic electrolysis is a function of:
Which type of needle/probe taper is generally preferred for treating fine vellus or sensitive facial hair in shallow follicles?
Hand-held forceps (epilating forceps) used during electrolysis must be:
AEA's Infection Prevention Standards (2023) require what type of indicator to verify each autoclave cycle?
Personal protective equipment for the electrologist must include at minimum:
Pitting or pock-marking of the skin after treatment most often results from:
Which medication, used for severe acne, is a strong relative contraindication for electrolysis until a washout period of typically 6 months has passed?
Why must reusable instruments be CLEANED of debris BEFORE sterilization?
What is the purpose of an exposure control plan (ECP) under OSHA's bloodborne pathogens standard?
Hepatitis B vaccination must be:
Folliculitis after electrolysis appears as:
To minimize post-treatment folliculitis, the electrologist should advise the client to:
Loading more…