What defines self-consolidating concrete (SCC) according to ACI 237R?
Scc Fundamentals
Question · Easy
Which ASTM standard covers the slump flow test for self-consolidating concrete?
Astm C1611
When performing the slump flow test per ASTM C1611, the final spread is calculated as:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
A typical target slump flow range for most SCC applications per ACI 237R is:
Question · Medium
During the slump flow test, the T50 time is:
A high T50 value (for example, 6 seconds) for SCC generally indicates:
In the slump flow test per ASTM C1611, the slump cone may be oriented:
When performing the C1611 test, consolidation of the SCC in the slump cone is:
Before performing the slump flow test, the base plate and inside of the slump cone should be:
Per ASTM C1611, the difference between the two diameter measurements during the slump flow test must not exceed:
The Visual Stability Index (VSI) is used to:
A VSI rating of 0 indicates:
A VSI rating of 3 indicates:
A VSI of 1 is characterized by:
The VSI assessment must be made:
ASTM C1621 tests passing ability of SCC using:
Astm C1621
The J-Ring used in ASTM C1621 has:
The J-Ring flow result in ASTM C1621 is expressed as:
Per ASTM C1621, a J-Ring flow difference of 0 to 1 in. (0 to 25 mm) indicates:
A J-Ring flow difference of more than 2 in. (50 mm) indicates:
During the C1621 test, when measuring the J-Ring flow diameter:
In ASTM C1621, the blocking step is:
Question · Hard
ASTM C1610 measures static segregation of SCC using:
Astm C1610
In ASTM C1610, after filling the column with SCC, the concrete must be allowed to rest undisturbed for approximately:
Per ASTM C1610, the static segregation value S is calculated as:
Per ACI 237R guidance, a typical acceptance limit for static segregation by ASTM C1610 column test is:
In ASTM C1610, the coarse aggregate content of each section is determined by:
ASTM C1712 is a rapid field test to assess:
Astm C1712
In ASTM C1712, the penetration depth is measured after:
Per ASTM C1712, what penetration depth result is considered indicative of a stable SCC (low segregation)?
ASTM C1758 governs:
Astm C1758
A key difference between ASTM C31 (conventional concrete) and ASTM C1758 (SCC) is that C1758 prohibits:
Per ASTM C1758, a standard 4x8 in. cylinder mold for SCC is filled:
If a particular SCC mix has shown signs of instability (VSI 2 or 3) during prior testing, ASTM C1758 recommends that specimens should still be fabricated:
The strike-off of SCC specimens in ASTM C1758 is done:
High-range water reducers (HRWRs) based on polycarboxylate ether (PCE) are commonly used in SCC because they:
A viscosity-modifying admixture (VMA) is used in SCC to:
Compared to conventional concrete, SCC mixes typically have:
ACI 237R describes the workability of fresh SCC in terms of three main properties:
Per ASTM C172 sampling requirements (which ACI SCC technicians must also know), the sample for SCC testing should be obtained:
Sampling Prerequisites
Which prerequisite certification must be valid before an individual can be certified as an ACI Self-Consolidating Concrete Testing Technician?
Certification
The ACI SCC Testing Technician certification is valid for:
The ACI SCC written exam is approximately:
The ACI SCC written exam passing requirements include:
During the performance examination for the ACI SCC certification, candidates must:
The slump flow test apparatus per ASTM C1611 uses a base plate that is:
When setting up for the slump flow test, the base plate must be:
Loading more…