Which organization develops the standardized ABC Water Treatment Class II examination used in most U.S. states?
State Laws Regulations
Question · Easy
Never enter a tank before testing the air
Short
ABC Water Treatment Class II certification typically authorizes operators to run treatment plants serving populations in which approximate range?
Inorganic coagulant salt whose hydroxide flocs dissolve if the pH climbs above about 8.
Treatment process
Guess the Term
Chapter 1: Source Water Quality & Characteristics
1.1 Hydrologic Cycle, Watersheds & Water Sources
Study guide
How many questions are on the standardized ABC Class II Water Treatment Operator examination?
Read the clue and guess the term in 6 tries.
Game
What minimum passing score is typically required to earn ABC Class II Water Treatment certification?
Aggregates that form when destabilized colloids join during gentle mixing and grow heavy enough to settle.
How much time is allotted to complete the ABC Class II Water Treatment examination?
Which federal law established the framework for drinking water quality regulation in the United States?
___ test: bench-scale trial in which raw water samples are dosed, mixed and settled to find the best coagulant dose.
1.2 Physical, Chemical & Biological Source Water Parameters
What does the abbreviation MCL stand for in drinking water regulation?
Swap tiles to line up three of the same term.
Term Match
What does MCLG stand for in EPA drinking water regulation?
V-shaped notch in a trough that draws settled water evenly off a basin and reduces short-circuiting.
Under the EPA Surface Water Treatment Rules, what is the minimum required log removal/inactivation for Giardia lamblia?
Water Treatment
What does CT stand for in drinking water disinfection calculations?
Powerful oxidant that reacts rapidly with organic and inorganic matter and whose residual is too unstable for the usual contact-time method.
1.3 Source Water Protection, Limnology & Raw Water Intakes
A treatment plant maintains a free chlorine residual of 1.0 mg/L with a baffled contact time of 30 minutes. What is the CT value achieved?
Flip two cards at a time to find matching terms.
Term Pairs
Which coagulant is most commonly used in conventional water treatment to destabilize suspended particles?
Internal wall or plate that lengthens the flow path in a contact basin and curbs short-circuiting from inlet to outlet.
Which iron-based coagulant is commonly used as an alternative to alum and performs well over a wider pH range?
What is the primary purpose of conducting a jar test in a water treatment plant?
Laboratory Testing
Collective name for the sand, anthracite and garnet layers inside a filter that catch particles.
Equipment operation and maintenance
1.4 Wellhead Protection, Source Water Protection & Watershed Management Plans
In rapid mixing (flash mixing) of coagulant, what mixing parameter is most important to optimize?
Question · Medium
Find five hidden terms in a grid of letters.
Term Search
What is the typical detention time range for a flocculation basin in conventional water treatment?
Plant-wide computer network that gathers readings from distant equipment and lets an operator adjust processes from a central console.
Which type of polymer is most commonly used as a coagulant aid to help build larger, denser floc?
What is the typical surface overflow rate (surface loading rate) for a conventional sedimentation basin treating coagulated surface water?
Rugged solid-state hardware that executes stored instructions to automate one machine or process, handling timing, counting and input/output.
1.5 Raw Water Storage, Release Scheduling & Demand Forecasting
In a sedimentation basin, what does the weir overflow rate (weir loading) measure?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which of the following filter media is typically placed at the top of a dual-media filter to provide coarse-to-fine filtration?
The most common kind of adjustable-speed motor controller: solid-state electronics that let an AC pump run over a wide speed range, with a 20 percent speed cut nearly halving power draw.
What is the typical filtration loading rate for a conventional rapid sand or dual-media gravity filter?
Which of the following is the most common reason to terminate a filter run and initiate backwash?
Haze scale on which conventional plants must keep 95 percent of monthly filtered-water readings at or below 0.3.
Laboratory analysis
Chapter 2: Coagulation & Rapid Mixing
2.1 Coagulation Chemistry & Colloidal Destabilization
What is the typical backwash rate range for a conventional rapid sand or dual-media filter?
Approximately how long does a typical filter backwash cycle last on a conventional gravity filter?
Field-test reagent whose color reaction measures the chlorine still left in treated water.
Loading more…