What is the primary purpose of a bar screen at the headworks of a wastewater treatment plant?
Abc Wastewater Treatment Class 1 Preliminary Primary
Question · Easy
Lockout/tagout, called like a cup final
Short
Which treatment step typically follows preliminary treatment in a conventional wastewater plant?
Chapter 1: Introduction, Plant Overview & Preliminary Screening
1.1 Exam Structure, Plant Layout & Unit Process Flow
Study guide
Why are grit chambers placed early in the treatment train?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What does BOD5 measure in a wastewater sample?
Abc Wastewater Treatment Class 1 Sampling Lab Math
What does TSS stand for and what does it measure?
Your heart has these. So do pipes.
What is the typical BOD5 of domestic raw wastewater entering a treatment plant?
Question · Medium
1.2 Bar Screens, Trash Racks & Mechanically Cleaned Screens
What does MLSS stand for in an activated sludge process?
Abc Wastewater Treatment Class 1 Secondary Biological
Which value represents the active biological fraction of mixed liquor?
What is RAS in an activated sludge plant?
Never enter a tank before testing the air
What is WAS in an activated sludge plant?
1.3 Comminutors, Macerators & Velocity-Controlled Grit Channels
What does the F/M ratio represent in activated sludge?
What does SRT (also called MCRT) measure?
A typical target dissolved oxygen (DO) level in a conventional activated sludge aeration tank is:
What is the most likely cause of sludge bulking in activated sludge?
Chapter 2: Grit Removal, Flow Equalization & Primary Clarification
2.1 Aerated Grit Chambers, Vortex Separators & Grit Handling
Stable, thick, brown-and-tan foam on an aeration basin most often indicates:
What is SVI (Sludge Volume Index) and what does a value of 100 mL/g typically indicate?
Which microscopic organism is generally an indicator of a healthy, mature activated sludge?
A typical primary clarifier removes approximately what percentage of influent BOD?
2.2 Primary Sedimentation Principles & Design Parameters
What is the typical detention time in a primary clarifier at average flow?
Which device skims scum and floating grease off the surface of a clarifier?
Which form of chlorine is typically delivered as a 12.5% liquid solution for wastewater disinfection?
Abc Wastewater Treatment Class 1 Disinfection Effluent
What is the typical detention time in a chlorine contact tank at average flow?
2.3 Primary Clarifier Operation, Sludge Pumping & Troubleshooting
Which chemical is most commonly used to dechlorinate effluent before discharge?
Why must chlorinated wastewater effluent typically be dechlorinated before discharge?
In UV disinfection of wastewater, what is the most common typical dose range?
Under EPA secondary treatment standards, the typical monthly average CBOD5 effluent limit is:
Abc Wastewater Treatment Class 1 Safety Collection Regs
Chapter 3: Secondary Biological Treatment — Activated Sludge Fundamentals
3.1 Activated Sludge Biochemistry & Aeration Tank Mechanics
What does NPDES stand for?
What is a DMR in wastewater operations?
Which type of sample is collected by combining sub-samples taken at intervals over 24 hours in proportion to flow?
Which parameters must be analyzed using a grab sample rather than a composite?
3.2 Process Control Parameters: F/M Ratio, MCRT & Sludge Wasting
The conversion factor 8.34 in wastewater math represents:
A 0.5 MGD plant is dosing chlorine at 5 mg/L. What is the chlorine feed rate in lb/day?
Detention time in a tank is calculated as:
Under EPA 40 CFR Part 503, Class A biosolids differ from Class B biosolids in that Class A:
Abc Wastewater Treatment Class 1 Solids Biosolids
3.3 Settleability Testing, Sludge Volume Index & Clarifier Blanket Dynamics
Aerobic digestion of waste activated sludge typically operates with a retention time of:
Loading more…