Performing Environmental Health Surveillance
12%of exam
Conducting Inspections
48%of exam
Conducting Investigations
18%of exam
Conducting Compliance Review
12%of exam
Providing Environmental Health Information
10%of exam
Quick Facts
- Credential
- NEHA REHS/RS
- Scope
- National credential exam
- Questions
- 225 multiple choice
- Scored
- 200 questions
- Pilot
- 25 unmarked questions
- Parts
- 113 plus 112 questions
- Testing Time
- 3 hours 40 minutes
- Break
- 10 minutes between parts
- Passing Score
- 650 scaled; not percent
Incidence vs Prevalence
Incidence
- New cases
- Population at risk
- Measures occurrence
Prevalence
- Existing cases
- Total population
- Measures burden
New flow vs existing pool
Surveillance Cycle
- Objective
- Define the decision need
- Case definition
- Standardize who counts
- Indicator
- Measure status or change
- Data source
- Match source to objective
- Collection
- Use consistent procedures
- Analysis
- Summarize person, place, time
- Interpretation
- Compare patterns and baselines
- Action
- Apply and evaluate controls
Epidemiology Math
- Incidence proportion
- New cases / population at-risk
- Prevalence
- Existing cases / population
- Attack rate
- Ill / exposed × 100
- Relative risk
- Attack exposed / attack unexposed
- Odds ratio
- Cross-products: ad / bc
- Sensitivity
- TP / (TP + FN)
- Specificity
- TN / (TN + FP)
- Case fatality
- Deaths / cases × 100
Sampling and QA
- Representative sample
- Reflects target population
- Random sample
- Known selection chance
- Chain of custody
- Documents possession and transfer
- Calibration
- Compare against known standard
- Field blank
- Detects field contamination
- Duplicate
- Checks sampling precision
- Accuracy
- Closeness to true value
- Precision
- Repeatability of measurements
Hazardous Waste ICRT
Ignitable | Corrosive | Reactive | Toxic
Cleaning vs Sanitizing
Cleaning
- Removes soil
- Uses detergent action
- Comes first
Sanitizing
- Reduces microorganisms
- Needs correct contact
- Follows cleaning
Remove soil before reducing microbes
Inspection Response
- Imminent health hazard?→Apply emergency authority
- Immediate correction possible?→Verify correction onsite
- Violation remains?→Document requirement and deadline
- Repeat noncompliance?→Escalate consistently
- Correction reported?→Verify with evidence
Inspection Workflow
- Pre-inspection
- Review history and authority
- Equipment
- Calibrate before field use
- Opening conference
- State scope and purpose
- Observation
- Follow process and product
- Measurement
- Use verified instruments
- Documentation
- Record objective evidence
- Corrective action
- Match risk and authority
- Closing conference
- Explain findings and deadlines
Inspection Five
Review | Observe | Measure | Document | Correct
MCL vs MCLG
MCL
- Legally enforceable
- Accounts for feasibility
- Public water standard
MCLG
- Health-based goal
- Not enforceable
- Sets desired protection
Standard vs health goal
Food Controls
- Cold holding
- 41°F or below
- Hot holding
- 135°F or above
- Cooling stage one
- 135°F to 70°F; two hours
- Cooling total
- 135°F to 41°F; six hours
- Reheat for holding
- 165°F within two hours
- Date marking
- Seven days at 41°F
- Cross-contamination
- Separate raw from ready-to-eat
- Sanitizing
- Reduce organisms after cleaning
Cross-Connection vs Backflow
Cross-connection
- Physical link exists
- Creates contamination pathway
- Prevent by separation
Backflow
- Flow actually reverses
- Pressure difference drives it
- Protect with approved device
Pathway vs reverse movement
Water and Wastewater
- MCL
- Enforceable contaminant limit
- MCLG
- Nonenforceable health goal
- Turbidity
- Cloudiness; treatment performance signal
- Coliforms
- Microbial indicator organisms
- Cross-connection
- Potable-to-contaminant physical link
- Backsiphonage
- Negative pressure reverses flow
- Backpressure
- Downstream pressure reverses flow
- Sanitary survey
- System vulnerability evaluation
RCRA vs CERCLA
RCRA
- Ongoing waste management
- Generation through disposal
- Cradle-to-grave controls
CERCLA
- Hazardous release response
- Contaminated-site cleanup
- Liability framework
Manage waste vs clean releases
Onsite Wastewater Systems
- Septic tank
- Settles solids; stores sludge
- Baffle or tee
- Controls inlet and outlet flow
- Effluent filter
- Retains suspended tank solids
- Distribution box
- Divides flow among laterals
- Soil absorption
- Treats and disperses effluent
- Biomat
- Biological interface layer
- Hydraulic overload
- Flow exceeds system capacity
- Surfacing effluent
- Failure requiring prompt action
Recreational and Built Facilities
- Free chlorine
- Available disinfectant residual
- Combined chlorine
- Chloramine-associated residual
- Total chlorine
- Free plus combined chlorine
- pH
- Controls chlorine effectiveness
- Turnover time
- Volume / flow rate
- Entrapment control
- Protect suction outlets
- Healthy housing
- Dry, clean, ventilated, pest-free
- Institution inspection
- Evaluate vulnerable-population safeguards
Facilities and Waste
- RCRA
- Active waste management framework
- CERCLA
- Release response and cleanup
- Ignitability
- Hazardous waste characteristic
- Corrosivity
- Hazardous waste characteristic
- Reactivity
- Hazardous waste characteristic
- Toxicity
- Hazardous waste characteristic
- Biomedical waste
- Segregate at generation
- Integrated pest management
- Prevent, monitor, control, evaluate
Risk Assessment Four
Hazard | Dose | Exposure | Characterize
Hazard vs Risk
Hazard
- Inherent harm potential
- Agent or condition
- Exists without exposure
Risk
- Probability and consequence
- Depends on exposure
- Includes uncertainty
Potential harm vs realized likelihood
Outbreak Investigation Path
- Excess illness suspected?→Confirm diagnosis and baseline
- Outbreak exists?→Define and find cases
- Cases assembled?→Describe person, place, time
- Pattern suggests exposure?→Develop testable hypothesis
- Hypothesis supported?→Trace source and control
- Controls implemented?→Evaluate and communicate
Outbreak Investigation
- Confirm diagnosis
- Review clinical and laboratory evidence
- Confirm outbreak
- Compare observed with expected
- Case definition
- Clinical, person, place, time
- Line list
- One row per case
- Epi curve
- Cases by onset time
- Hypothesis
- Testable exposure explanation
- Traceback
- Follow product distribution chain
- Control measures
- Interrupt exposure or transmission
Descriptive Epidemiology
Person | Place | Time
Risk Assessment
- Hazard identification
- Can the agent cause harm?
- Dose-response
- How dose changes effect
- Exposure assessment
- Who, how much, how long
- Risk characterization
- Integrate risk and uncertainty
- Exposure route
- Inhalation, ingestion, dermal
- Sensitive population
- Greater susceptibility or exposure
- Risk management
- Choose and implement controls
Vector and Indoor Air
- Vector surveillance
- Track species and abundance
- Source reduction
- Remove breeding habitat
- Reservoir
- Maintains agent in nature
- Moisture
- Primary mold-growth control
- Carbon monoxide
- Combustion gas; impairs oxygen delivery
- Ventilation
- Dilutes indoor contaminants
- Complaint history
- Guides inspection scope
HACCP Seven
Hazards | CCPs | Limits | Monitor | Correct | Verify | Record
Verification vs Validation
Verification
- System follows plan
- Records and calibration
- Ongoing confirmation
Validation
- Controls can work
- Scientific or technical basis
- Established before reliance
Doing it right vs effective
HACCP Control Decision
- Significant hazard present?→Identify preventive control
- Step controls hazard?→Evaluate as CCP
- CCP confirmed?→Set measurable critical limit
- Limit can drift?→Define monitoring
- Deviation occurs?→Apply corrective action
- System operates?→Verify and retain records
HACCP Seven Principles
- Principle 1
- Conduct hazard analysis
- Principle 2
- Determine critical control points
- Principle 3
- Establish critical limits
- Principle 4
- Establish monitoring procedures
- Principle 5
- Establish corrective actions
- Principle 6
- Establish verification procedures
- Principle 7
- Establish records and documentation
Plan and Compliance Review
- Plan review
- Prevent problems before construction
- Flow diagram
- Trace process and hazards
- Critical limit
- Measurable CCP boundary
- Variance
- Approved departure from rule
- Permit status
- Verify authority to operate
- Compliance evidence
- Records, observation, measurement
- Technical assistance
- Explain compliant control options
Enforcement Ladder
- Education
- Clarify requirement and risk
- Correction
- Remove immediate violation
- Written notice
- Document violation and deadline
- Reinspection
- Verify sustained compliance
- Administrative action
- Escalate under governing authority
- Due process
- Notice and hearing opportunity
- Consistency
- Apply policy uniformly
NEHA Credential vs State License
NEHA REHS/RS
- National credential
- NEHA eligibility
- Current five-domain outline
State credential
- Jurisdiction-specific authority
- State eligibility
- May use different exam
Confirm governing credential first
Public Message Selection
- Immediate action needed?→Lead with protective action
- Evidence incomplete?→State uncertainty plainly
- Audience is technical?→Add methods and limits
- Audience is public?→Use plain language
- Message released?→Monitor understanding and update
Risk Communication
- Audience
- Identify needs and concerns
- Core message
- State risk and action
- Plain language
- Use familiar concrete terms
- Uncertainty
- Acknowledge what remains unknown
- Empathy
- Recognize concern before facts
- Consistency
- Coordinate messages across partners
- Feedback
- Check understanding and response
Emergency Information
- Preparedness plan
- Define hazards, roles, resources
- Incident command
- Scalable response structure
- Unified command
- Shared authority across agencies
- Situation report
- Current facts and actions
- Public advisory
- Specific protective action
- Recovery
- Restore and monitor services
- After-action review
- Capture gaps and improvements
Common Traps
Old Blueprint vs Current
Current outline has five domains ≠ Do not use six-domain brochure
Total vs Scored
Exam presents 225 questions ≠ Blueprint allocates 200 scored items
Scaled vs Percent
Passing scaled score is 650 ≠ It is not 65 percent
Model Code vs Local Law
FDA Food Code is model guidance ≠ Jurisdictions adopt enforceable versions
Inspection vs Investigation
Inspection checks regulated conditions ≠ Investigation resolves cause or complaint
Negative Sample vs Safety
Sampling covers limited material ≠ Negative result proves no universal absence
Correlation vs Causation
Association can support hypotheses ≠ Causation needs converging evidence
Correction vs Compliance
Immediate correction removes condition ≠ Compliance prevents recurrence
Disinfectant vs Clarity
Clear water can remain unsafe ≠ Verify chemistry and treatment
Message Detail vs Action
Protective action comes first ≠ Technical detail follows audience needs
Last Minute
- 1.National NEHA credential; not state variant
- 2.225 total; 200 scored; 25 pilot
- 3.Parts: 113 plus 112 questions
- 4.Time: 110 minutes each part
- 5.Break: 10 minutes
- 6.Passing score: 650 scaled
- 7.Surveillance: 12%; 24 scored items
- 8.Inspections: 48%; 96 scored items
- 9.Investigations: 18%; 36 scored items
- 10.Compliance review: 12%; 24 scored items
- 11.Information: 10%; 20 scored items
- 12.Food Code edition: 2017
- 13.Cold ≤41°F; hot ≥135°F
- 14.Cooling: 135→70°F within two hours
- 15.Cooling: 135→41°F within six hours
- 16.Attack rate = ill / exposed
- 17.Hazard, dose-response, exposure, characterization
- 18.HACCP: seven ordered principles
- 19.Document objective inspection evidence
- 20.Lead public messages with action
Explore More NEHA Environmental Health Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.
