Surface Preparation and Inspection

18%of exam

Blast LevelsWJ LevelsISO GradesConcrete PrepPrep Picker

Coating Inspection

16%of exam

DFT MethodsAdhesion TestsHoliday DetectionFailure ModesNDE Methods

Inspection Process

15%of exam

RolesITPHold PointsEscalation

Coatings and Coating Application

13%of exam

Specialty SystemsCure TypesWFT/DFT MathApplication Methods

Documentation

10%of exam

Galvanizing StandardsReportsNCRsDaily Logs

Corrosion

9%of exam

Corrosion FormsCathodic ProtectionCD TestingCorrosion Mitigation

Environmental Conditions and Inspection

7%of exam

Dew Point RuleRH ThresholdInstrumentsFlash Rust

Safety

4%of exam

Stop-Work HazardsIntrinsically SafeConfined SpacePPE

Communications and Teamwork

4%of exam

Owner vs ContractorLevel 3 EscalationConflict ResolutionStakeholder Communication

Ethics

4%of exam

Pressure PointsReporting DutyConflicts of InterestInspector Limits

Quick Facts

Exam
CIP Level 2
Body
AMPP
Items
120 (100 scored)
Time
3 hrs seat time
Practical
8 stations, in-person
Pass score
Not published
Prereq
CIP-1 + 2 yrs exp
Validity
3 years

Blast Level Order

SP7 < SP6 < SP10 < SP5 cleanliness

SP7: brush-off, lightest levelSP6: commercial, 33% stainSP10: near-white, 5% stainSP5: white metal, zero stain

SP6 vs SP10

SP6 / NACE No.3

  • Commercial blast
  • Sa 2 equivalent
  • ≤33% staining allowed

SP10 / NACE No.2

  • Near-white blast
  • Sa 2½ equivalent
  • ≤5% staining allowed

Moderate vs high-performance service

Surface Prep Standard Picker

  1. Immersion, TSA, or IOZ serviceSP5 / NACE No.1(Sa 3, zero stain)
  2. Moderate atmospheric maintenance coatingSP10 / NACE No.2(Sa 2½, ≤5% stain)
  3. General industrial maintenance workSP6 / NACE No.3(Sa 2, ≤33% stain)
  4. Shop primer or temp protectionSP7 / NACE No.4(Sa 1, lightest blast)
  5. Blasting is impractical onsiteSP11 power tool(Bare metal, min profile)
  6. Galvanized or non-ferrous metalSP16 brush-off blast(Keep substrate layer intact)
  7. Need soluble-salt removalWaterjetting WJ series(No new profile created)
  8. Confined space or elevated accessRemote/portable prep equipment(Keeps crew out of hazard)

SSPC/NACE Blast Levels

SP1
Solvent cleaning, removes oil/grease
SP2
Hand tool cleaning, loose material
SP3
Power tool cleaning, loose material
SP5 / NACE No.1
White metal blast, zero stainingSa 3
SP6 / NACE No.3
Commercial blast, ≤33% stainingSa 2
SP7 / NACE No.4
Brush-off blast, lightest levelSa 1
SP10 / NACE No.2
Near-white blast, ≤5% stainingSa 2½
SP11
Power tool cleaning to bare metal

WJ Cleanliness Ladder

WJ-1 cleanest, WJ-4 lightest cleaning level

WJ-1: bare substrateWJ-2: 95% clean matteWJ-3: two-thirds cleanWJ-4: light, adherent stays

Waterjetting WJ Levels

WJ-1
Clean to bare substrate≈SP5
WJ-2
Very thorough, ≥95% residue-free≈SP10
WJ-3
Thorough, ≥2/3 residue-free≈SP6
WJ-4
Light cleaning, adherent matter stays≈SP7

ISO 8501-1 Grades

Sa 1
Light blast cleaning
Sa 2
Thorough blast cleaning
Sa 2½
Very thorough blast, slight stains
Sa 3
Blast to visually clean steel
St 2
Thorough hand tool cleaning
St 3
Very thorough power tool cleaning

Abrasive & Concrete Prep

SSPC-AB 1
Mineral and slag abrasive quality
SSPC-AB 2
Recycled ferrous abrasive work mix
SSPC-AB 3
New unused ferrous metallic abrasive
SP16
Brush-off blast, galvanized/non-ferrous metals
ASTM D4259
Concrete abrasion prep, removes laitance
ICRI 310.2R
Concrete profile scale, CSP 1-9

Holiday Voltage Crossover

Under 20 mils wet, over dry-spark

Under 20 mil: low voltageOver 20 mil: high voltageFormula: V equals M root DFT

Verification vs Calibration

Verification

  • Field check
  • Every shift
  • No adjustment made

Calibration

  • Lab or tech performed
  • Periodic interval
  • Adjusts the instrument

Confirm vs correct

Thickness & Adhesion Test Picker

  1. DFT on steel substrateMagnetic/eddy-current gauge(Per SSPC-PA 2)
  2. DFT on concrete, FRP, woodUltrasonic gauge(ASTM D6132)
  3. Need pass/fail adhesion classD3359 tape test(Qualitative rating only)
  4. Need numeric adhesion valueD4541 pull-off(Force/area plus failure mode)
  5. Cure check on rigid FRPBarcol hardness (D2583)(Shore D saturates near 100)
  6. Cure check on flexible liningShore D durometer (D2240)(Stays sensitive to cure)
  7. Coating under 20 mils DFTLow-voltage wet sponge(Holiday test method)
  8. Coating over 20 mils DFTHigh-voltage spark tester(V = M√DFT)

Profile & DFT Methods

D4417 Method A
Visual comparator, profile range
D4417 Method B
Depth micrometer, max reading recorded
D4417 Method C
Replica tape, peak-to-valley depth
D6132
Ultrasonic DFT, non-metallic substrates
Magnetic/eddy-current gauge
DFT on steel substrates

Failure Mode Clues

Salts blister, thick film mud-cracks, humidity blushes

Osmotic blister: soluble saltsMud-cracking: over-thick filmAmine blush: humid cure

WFT vs DFT

WFT

  • Measured wet
  • Before cure
  • Predicts final DFT

DFT

  • Measured cured
  • Spec compliance value
  • Pass/fail basis

Wet predicts, dry decides

Adhesion & Hardness Tests

D4541
Pull-off adhesion, force plus mode
D3359
Tape test, qualitative classification
D2583
Barcol hardness, rigid FRP
D2240
Shore D hardness, flexible linings
Tooke gauge
Cross-section reveals coat thicknesses

Low- vs High-Voltage Holiday

Low voltage

  • Wet sponge
  • Under 20 mils
  • Water completes circuit

High voltage

  • Spark/brush probe
  • Over 20 mils
  • V = M√DFT

Thin film vs thick film

Holiday Detection

Low voltage
Wet sponge, under 20 mils
High voltage
Spark tester, over 20 mils
D5162
Holiday testing, metal substrates
D4787
Holiday testing, concrete substrates
V = M√DFT
Voltage formula, AMPP SP0188

D3359 vs D4541

D3359 tape test

  • Qualitative rating
  • Cross-cut classification
  • Pass/fail only

D4541 pull-off

  • Quantitative force value
  • Failure mode noted
  • PSI or MPa

Classify vs quantify

Cure & Finish Checks

D5402
Solvent rub resistance, cure check
D523
Gloss measured at 60 degrees
Calibration
Lab adjusts against reference standard
Verification
Field check, no adjustment made

Coating Failure Modes

Osmotic blistering
Soluble salts draw in moisture
Cathodic disbondment
CP current lifts coating edge
Mud-cracking
Over-thick film shrinks, cracks
Alligatoring
Hard topcoat over soft undercoat
Amine blush
Humidity during epoxy cure
Filiform corrosion
Thread-like rust under film

NDE Methods

VT
Visual testing, needs adequate light
PT
Dye penetrant, surface-breaking defects
MT
Magnetic particle, ferromagnetic only
UT
Ultrasonic, volumetric defects
RT
Radiographic, volumetric defects

Escalation & Authority Picker

  1. Widespread or recurring failureEscalate to CIP Level 3(Root-cause determination)
  2. Verbal request conflicts with specWritten spec still governs(Get change in writing)
  3. Contractor pressures skipping a testHold to spec, report facts(Escalate if pressure continues)
  4. Spec interpretation is ambiguousRoute to owner or engineer(Not resolved onsite alone)

Inspection Process & Roles

ITP
Inspection and test plan, pre-work
Hold point
Work stops for required sign-off
Owner/engineer
Sets criteria, final disposition call
Contractor
Chooses means and methods
Inspector
Verifies work meets specification
De facto standard
Common practice, no formal body

Convertible vs Non-Convertible Cure

Convertible

  • Chemical cure reaction
  • Irreversible once cured
  • Epoxy, polyurethane

Non-convertible

  • Solvent/water evaporation only
  • Re-softens in solvent
  • Vinyl, chlorinated rubber

React vs evaporate

Specialty Coating Systems

Thermal spray
AWS C2.23M / SSPC-CS 23.00
Thermal spray guide
AWS C2.18, selection guidance
Pipeline FBE
100% holiday tested at mill
3LPE
Polyethylene jacket, standard temperature service
3LPP
Polypropylene jacket, high-temperature service
Polyurea
Plural-component, mixed at spray tip

WFT/DFT Formulas

WFT formula
WFT = DFT ÷ %VS
Thinner correction
Raises WFT needed for target DFT
Spreading rate
m2/L = %VS x10 / DFTum
Volume solids
Percent resin/pigment left after cure

Galvanizing & Doc Standards

ASTM A123
Original hot-dip galvanized coating spec
ASTM A780
Field repair of damaged galvanizing
NCR
Non-conformance record, documents deviation
Daily log
Records conditions, activities, and results

Corrosion Forms

Galvanic corrosion
Dissimilar metals, electrolyte contact
Pitting corrosion
Localized, chloride-driven attack
Crevice corrosion
Stagnant electrolyte, tight gaps
SCC
Stress corrosion cracking, tensile plus environment
MIC
Microbiologically influenced corrosion

Cathodic Protection

ICCP
Impressed current, rectifier power source
Galvanic anodes
Sacrificial zinc, aluminum, or magnesium
Rectifier
Converts AC to DC current
SP0169
Buried/submerged pipeline CP standard
Anode selection
Small/isolated favors galvanic anodes

Cathodic Disbondment Lab Tests

ASTM G8
Room-temperature immersion CD test
ASTM G42
Elevated-temperature CD test
ASTM G80
Specific cathodic disbonding test
ASTM G95
Attached-cell CD test method

Dew Point Margin

Five degrees F, three C, above

Applies during prep, coat, cureSSPC-PA 1 states the ruleBelow margin risks moisture

Environmental Rules & Instruments

Dew point rule
Surface 5°F (3°C) above dew point
RH threshold
Above 60% RH accelerates flash rust
Psychrometer
Measures relative humidity
Surface thermometer
Contact probe, steel temperature
D4285
Blotter test, oil/water in air

Intrinsically Safe Equipment

Verify ratings before confined space entry

Limits electrical, thermal ignition energyCheck before tanks, confined spacesCertified for flammable atmospheres present

Inspector Authority vs Contractor Responsibility

Inspector

  • Verifies the work
  • Reports facts objectively
  • No means/methods say

Contractor

  • Chooses means/methods
  • Performs the work
  • Meets spec requirements

Judge vs performer

Common Traps

Wet sponge ≠ spark tester

Low voltage under 20 mils High voltage over 20 mils

Calibration ≠ verification

Calibration adjusts the instrument Verification only checks reading

Visual clean ≠ salt-free

Visual grade misses invisible salts Salts need a separate test

Tape test ≠ pull-off

Tape gives a class rating Pull-off gives a force value

Waterjetting ≠ new profile

Waterjetting only cleans the surface It creates no new profile

Sa 2½ ≠ Sa 3

Sa 2½ allows slight staining Sa 3 allows zero staining

Verbal request ≠ spec change

Verbal input is context only Written spec still governs plans

Bulging hose ≠ minor issue

Bulge signals lining/reinforcement failure Treat as immediate stop-work hazard

Schedule pressure ≠ valid reason

Compression tempts skipping hold points Spec requirements still fully apply

Last Minute

  1. 1.Prep 18%, Inspection 16%, Process 15%
  2. 2.120 items: 100 scored, 20 unscored
  3. 3.3-hour seat time, no passing score
  4. 4.SP5/NACE1 = white metal, zero stain
  5. 5.SP10/NACE2 = near-white, 5% stain max
  6. 6.SP6/NACE3 = commercial, 33% stain max
  7. 7.WJ-1 cleanest, WJ-4 lightest waterjet level
  8. 8.Dew point: 5°F/3°C above surface
  9. 9.Holiday test: wet sponge under 20mil
  10. 10.Holiday test: spark tester over 20mil
  11. 11.D4541 = numeric pull-off force value
  12. 12.D3359 = qualitative tape classification only
  13. 13.Calibration adjusts; verification only confirms reading
  14. 14.Barcol (D2583) rigid FRP; Shore flexible
  15. 15.Written spec governs over verbal requests
Same family resources