According to ACI 318, what is the minimum required concrete clear cover for reinforcing steel cast directly against and permanently exposed to earth or soil?
Subgrade And Supports
Question · Easy
OSHA fall heights, to scale
Short
What is the minimum concrete clear cover required for #7 reinforcing bars in cast-in-place concrete that will be exposed to weather after form removal?
What is the minimum concrete clear cover for a #4 rebar mat installed in a concrete wall exposed to weather after forms are stripped?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
For an interior elevated concrete floor slab not exposed to weather or earth, what is the minimum clear concrete cover required for #5 reinforcing bars?
Question · Medium
Which requirement applies to precast concrete block supports ('dobies') used to elevate rebar mats above the subgrade in footings?
What is the maximum recommended spacing between continuous slab bolsters or individual chairs supporting a mat of #4 rebar in a concrete slab per CRSI placing standards?
According to ACI 318, what is the minimum clear spacing required between parallel reinforcing bars placed in a single horizontal layer in a beam?
Per ACI 117, what is the specified placement tolerance for concrete cover on a member with a depth of 8 inches or less where the specified cover is 1.5 inches?
Question · Hard
When installing epoxy-coated reinforcing bars in a concrete parking deck, what type of bar supports must be used?
According to ACI 318, what is the minimum clear distance required between longitudinal vertical bars in a reinforced concrete column?
A structural slab drawing calls for an 8-inch thick slab with #5 rebar bottom mats supported by dobies. If the plans specify 3/4 inch clear cover at the bottom, at what height above the subgrade form must the bottom of the #5 rebar be positioned?
When installing rebar supports over a plastic vapor retarder on a prepared subgrade, what practice prevents puncturing the moisture membrane?
When parallel reinforcing bars are placed in two or more upper and lower horizontal layers in a deep beam, what is the minimum clear vertical distance required between the layers?
A grade beam footing is 24 inches wide and requires 3 inches of clear concrete cover on all sides cast against earth. What is the maximum outside-to-outside width dimension of a transverse stirrup or tie designed to fit inside this grade beam?
Under CRSI standards for metal bar supports, what does the designation 'SB' represent?
What is the nominal diameter of a standard #6 deformed steel reinforcing bar?
Bar Handling And Fabrication
What is the nominal weight per linear foot of a standard #5 deformed reinforcing bar?
A rebar bundle delivered to the site contains 50 stock lengths of #7 rebar, with each piece measuring 40 feet long. Standard #7 bar weighs 2.044 lbs per linear foot. What is the total weight of the bundle?
On a mill-stamped reinforcing bar, which letter symbol designates low-alloy steel specifically manufactured to meet ASTM A706 weldability standards?
How is Grade 60 reinforcing steel identified by longitudinal grade lines under standard ASTM bar marking rules?
Per ACI 318, what is the minimum inside bend pin diameter for forming standard 90-degree main structural hooks on #3 through #8 reinforcing bars?
What is the standard straight extension length required at the free end of a standard 90-degree hook for main flexural reinforcement per ACI 318?
What is the required extension length at the free end of a standard 180-degree bend hook per ACI 318?
What is the minimum inside bend pin diameter required for standard hooks on #10 reinforcing bars per ACI 318?
If field heating of reinforcing steel is authorized by the Licensed Design Professional (LDP) to facilitate bending or straightening, what maximum temperature must not be exceeded?
How should damaged epoxy coating on rebar (scratches or cut ends) be repaired in the field per ASTM A775 and CRSI standards?
What is the minimum straight extension required at the free end of a 135-degree seismic hook on a #4 stirrup per ACI 318?
According to ACI 117 standard tolerances, what is the allowable fabrication tolerance on the overall length of straight sheared reinforcing bars (#3 through #11)?
How should rebar bundles be stored when delivered to a construction jobsite prior to placement?
Regarding surface rust on rebar prior to concrete placement, what is the ACI 318 rule?
According to ACI 318, what is the range of clear spacing (pitch) permitted between turns of continuous spiral reinforcement in a column?
For Grade 60 deformed bars, what is the minimum ratio of temperature and shrinkage reinforcement area to gross concrete area (Ag) required in structural slabs per ACI 318?
A 6-inch thick structural floor slab requires Grade 60 temperature steel at the minimum ACI ratio of 0.0018. What is the minimum required steel area per linear foot (12 inches) of slab width?
Which ASTM standard specification governs stainless steel deformed bars used for concrete reinforcement in highly corrosive environments?
Which ASTM standard specification covers hot-dip zinc-coated (galvanized) steel bars used for reinforcing concrete?
What is the standard wire gauge size most commonly used by rodbusters for hand-tying reinforcing steel on job sites?
Placing And Tying
Which tying knot technique is the simplest and fastest, used primarily on flat horizontal slab mats where rebar is not subject to displacement?
When assembling vertical wall mats, which tying technique is recommended to prevent vertical bars from slipping downward along horizontal bars?
Which tying knot involves passing wire around the back of a carrier bar, extending both ends up on opposite sides of the intersecting bar, and twisting above the cross bar (forming a U-shape)?
Which tying method provides maximum rigidity for heavy column cages and beam intersections subject to extreme hoisting stresses?
What is the general CRSI guideline for tying rebar intersections in flat slab mats supported on chairs?
What type of tie wire must be used when securing epoxy-coated reinforcing bars?
In a rectangular two-way reinforced concrete floor slab, which bottom layer of steel reinforcement is placed first on the chairs?
Where must primary tension reinforcing steel be placed in a cantilevered concrete slab (such as an exterior balcony)?
What rebar detail is required around rectangular slab penetrations (such as duct openings) to prevent re-entrant corner cracking?
A concrete wall mat is 20 feet long by 10 feet high. Vertical bars are spaced at 12 inches on center (21 vertical bars total) and horizontal bars are spaced at 12 inches on center (11 horizontal bars total). How many total bar intersections exist in this single curtain wall mat?
Loading more…