Which structure within an X-ray tube is responsible for producing electrons via thermionic emission?
Anatomy And Physiology
Question · Easy
In diagnostic radiography, what does increasing the kVp setting primarily affect?
Which imaging modality relies on the piezoelectric effect to generate and receive sound waves?
Nursing & Healthcare Exam Prep Podcast
Listen on Spotify
Podcast
Iodinated contrast media used in CT examinations primarily enhance image contrast by which mechanism?
Question · Medium
In MRI, the Larmor frequency of hydrogen protons is directly proportional to which factor?
A chest X-ray shows the heart shadow occupying more than 50% of the thoracic diameter. Which anatomical condition does this most likely indicate?
Which physiological effect is of greatest concern when a patient with a ferromagnetic implant enters the MRI scan room?
What is the maximum permissible whole-body occupational radiation dose limit per year for a radiation worker in the United States?
Public Safety
Which type of personal radiation monitoring device provides an immediate, real-time dose reading?
According to NFPA 99, what is the maximum allowable leakage current from a patient-applied medical device?
What is the primary purpose of the lead apron worn by staff during fluoroscopy procedures?
Under FDA/CDRH regulations, which class of medical device recall indicates the highest risk of serious adverse health consequences or death?
A CRES technician discovers a frayed power cord on a portable X-ray unit. What is the correct immediate action?
What is the recommended minimum frequency for performing electrical safety inspections on patient-care medical equipment in a hospital?
During infection control procedures, which level of disinfection is required for ultrasound transducers used in transvaginal or transrectal examinations?
According to Ohm's Law, if a circuit has a voltage of 120V and a resistance of 60 ohms, what is the current?
Electronics Fundamentals
In an AC circuit, what is the phase relationship between voltage and current in a purely capacitive load?
What is the primary function of a full-wave bridge rectifier in an X-ray generator?
A transformer has a primary winding of 200 turns and a secondary winding of 1,000 turns. If the primary voltage is 220V, what is the secondary voltage?
Which electronic component stores energy in an electric field and blocks DC while allowing AC to pass?
What is the total resistance of three resistors (10Ω, 20Ω, and 30Ω) connected in parallel?
In a digital logic circuit, what is the output of an AND gate when both inputs are HIGH (1)?
What type of power supply regulation maintains a constant output voltage despite variations in input voltage or load current?
A bipolar junction transistor (BJT) in an X-ray generator control circuit is operating in saturation mode. What does this indicate?
What component in an X-ray generator uses a thyristor (SCR) to precisely control exposure timing?
In a high-frequency X-ray generator, what advantage does the inverter circuit provide over conventional single-phase or three-phase designs?
Healthcare Technology And Function
What is the primary purpose of the rotating anode in a diagnostic X-ray tube?
During preventive maintenance on a CT scanner, the CTDI (Computed Tomography Dose Index) measurement is found to be 25% higher than the manufacturer's baseline specification. What is the most appropriate action?
In CT imaging, what do Hounsfield units (HU) measure?
What is the primary safety concern associated with the quench of a superconducting MRI magnet?
Which component in an MRI system is responsible for spatial localization of the signal?
During a mammography unit quality control check, the measured half-value layer (HVL) is below the minimum required value. What does this indicate?
Question · Hard
What is the primary advantage of a flat-panel digital detector over a computed radiography (CR) cassette system?
During preventive maintenance on a fluoroscopy system, the measured entrance skin dose rate exceeds the regulatory limit of 88 mGy/min (10 R/min) for standard fluoroscopy. What is the required action?
What is the function of the automatic brightness control (ABC) system in a fluoroscopy unit?
A portable X-ray unit uses a rechargeable battery-powered capacitor discharge generator. What is the main limitation of this design?
During preventive maintenance on an ultrasound system, the CRES technician performs a tissue-mimicking phantom scan. The measured axial resolution is significantly worse than the manufacturer's specification. Which component is the most likely cause?
What is the primary purpose of the collimator on a diagnostic X-ray tube housing?
A C-arm fluoroscopy unit displays an error indicating that the anode heat capacity has reached 80%. What should the CRES technician advise?
What is the purpose of the Dose Length Product (DLP) in CT scanning?
A CT scanner's detector calibration (air calibration) should be performed in which situation?
What is the Specific Absorption Rate (SAR) in MRI, and why is it monitored?
A mammography system uses a molybdenum (Mo) anode with a molybdenum filter. For which breast type is this target/filter combination most appropriate?
What is the standard preventive maintenance interval recommended by most manufacturers for diagnostic X-ray tube housing leakage radiation testing?
Which calibration tool is used to verify the accuracy of a CT scanner's Hounsfield unit measurements?
A CRES technician is troubleshooting a digital radiography (DR) system that produces images with a consistent vertical line artifact. What is the most probable cause?
Healthcare Technology Problem Solving
A CT scanner produces ring artifacts in every scan. Which troubleshooting step should the CRES technician perform first?