Free Journeyman Plumber Practice Test by State: 2026 Guide
Video
Under 2025 California Plumbing Code (CPC) Table 702.1, what is the minimum trap and drain pipe size required for a water closet?
Planning And Estimating
Question · Easy
Find 45 plumber practice routes across 44 states and DC, confirm your actual credential and references, and work through source-bounded code and trade-math examples.
Blog
Under 2025 CPC Section 708.1, when a 1/4-inch-per-foot slope is impracticable due to street sewer depth or structural features and the Authority Having Jurisdiction approves a reduced grade, what is the minimum allowable slope for a 4-inch horizontal drainage pipe?
Underground And Rough Systems
Under 2025 CPC Table 702.1, what is the drainage fixture unit (DFU) value assigned to a private residential lavatory?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Per the CPC as adopted in California, what is the minimum depth of a fixture trap seal?
Finish Plumbing Installations
According to 2025 CPC Sections 707.4 and 719.1, at what maximum horizontal interval must cleanouts be installed on straight runs of horizontal drainage piping?
Using 2025 CPC Table 702.1, a commercial restroom group contains four public 1.28 GPF water closets (4 DFU each), two public lavatories (1 DFU each), and one floor drain (2 DFU). What is the total connected DFU load?
Question · Medium
Per 2025 CPC Section 708.1, what is the minimum uniform slope required for a 2-inch horizontal drainage pipe?
A horizontal building drain at 1/4 inch per foot serves seven private 1.28-gpf water closets and no other fixtures. The load is 21 DFU. Under 2025 CPC Table 703.2, what is the smallest listed pipe size that satisfies both the DFU capacity and the water-closet count limit?
Under 2025 CPC 1001.1, what is the maximum vertical distance from a fixture outlet to the trap weir?
When calculating sanitary branch loads from 2025 CPC Table 702.1, how many drainage fixture units (DFU) does a residential bathtub with an overhead combination shower represent?
A dry vent is being connected to a horizontal sanitary drain. Under 2025 CPC 905.2, where must the vent connection be taken off the drain?
Under 2025 CPC Table 707.1, what is the minimum required cleanout plug size for a 4-inch horizontal drainage pipe?
A bid takeoff requires 180 feet of pipe. The estimate allows 10% additional length for cutting waste. Pipe is purchased only in 20-foot lengths. How many full lengths should be included?
Which listed assembly is suitable under 2025 CPC Table 603.2 for a health-hazard connection subject to both backpressure and backsiphonage?
Under 2025 CPC 408.4.2, what is the maximum shower discharge temperature that the required point-of-use control must limit?
Under the CPC as adopted in California, what is the minimum water supply pipe size for a single-family dwelling?
For an ordinary installation without a specific AHJ-approved exception, 2025 CPC 608.2 requires excessive static supply pressure to be reduced to no more than what value?
Under 2025 CPC Table 610.3, what is the minimum nominal fixture branch pipe size listed for a domestic kitchen sink, before selecting any listed fixture connector?
A domestic storage water heater is supplied through a check valve that prevents expanded water from returning to the supply. Under 2025 CPC 608.3, which condition requires approved thermal expansion control?
A T&P relief valve has a 3/4-inch outlet. Under 2025 CPC 608.5, what is the minimum discharge-pipe size throughout the run?
A proposed building sewer uses material approved for sewer use but not approved for use within a building. Under 2025 CPC 718.3, what minimum distance from the building must be maintained for that material?
Under 2025 CPC Section 603.5.6.3, what backflow protection is required on a potable water supply serving a lawn irrigation system equipped with a chemical or fertilizer injection pump?
Where 2025 CPC 507.5 requires a drained water-heater pan, what is the minimum pan-drain diameter?
A T&P relief discharge terminates outside the building under 2025 CPC 608.5. What height above the ground is required?
Under 2025 CPC Sections 609.2 and 720.0, when a potable water pipe shares a trench with or crosses over a clay building sewer not approved for use within a building, what is the minimum vertical separation above the top of the sewer?
At the design flow, the available pressure at the service is 50 psi. Elevation consumes 26 psi and piping plus meter friction consumes 16 psi. What residual pressure is available at the highest fixture?
For an ordinary water-closet installation not subject to an additional accessible-clearance requirement, what minimum clear space in front does 2025 CPC 402.5 require?
For an ordinary nonaccessible water closet or bidet, what minimum side-wall distance from the fixture centerline does 2025 CPC 402.5 require?
In a new shower installation that is not a bathtub-to-shower retrofit using Table 702.1 footnote 9, what is the minimum trap and trap-arm size under 2025 CPC Table 702.1?
For an adult accessible lavatory without a height exception, 2025 CBC 11B-606.3 measures the front of the higher of the rim or counter surface. What is its maximum height above the finished floor?
In 2025 CPC Table 702.1, which flush-volume boundary separates the 3-DFU private water-closet row from the 4-DFU private higher-volume row?
The approved toilet’s installation drawing specifies a 12-inch rough-in from the finished rear wall to the flange center. Tile and backing will add 3/4 inch beyond the present wall face. Where should the flange center be marked from the present wall face?
Under 2025 CPC 407.2.1, what maximum flow at 60 psi is permitted for a nonmetering public-restroom lavatory faucet?
Under 2025 CPC 408.8.3, what is the minimum sheet-lead weight for a site-fabricated shower liner?
Under 2025 CPC Table 702.1, what is the minimum trap and trap-arm size for an ordinary floor drain?
At an adult accessible water closet, what height to the top of the horizontal grab bar’s gripping surface is required by 2025 CBC 11B-609.4?
A food-preparation sink requires an indirect drainage connection through an air gap under 2025 CPC 801.3.3. Under 801.2, what is the minimum vertical drainage air gap between the pipe outlet and the receptor’s flood-level rim?
Per the CPC as enforced in California, what is the minimum trap size for a residential bathtub?
A 3-inch service-sink drain carries 3 DFU. Its individual vent will be 20 feet developed length, of which 5 feet is horizontal. Excluding water closets and six-unit traps, what is the minimum vent diameter under 2025 CPC 904.1 and Table 703.2?
For an ordinary roof termination without a frost or occupied-roof special condition, what minimum height above the roof does 2025 CPC 906.1 require for a vent?
A vent outlet is less than 3 feet above an operable window. Under 2025 CPC 906.2, what minimum horizontal separation is required?
An installer proposes an air admittance valve that is not a prescriptive Chapter 9 vent arrangement. Under 2025 CPC 301.3, what should occur before installation?
A horizontal bathroom-group wet-vent segment carries 4 DFU before the water closet connects downstream. Under 2025 CPC 908.2.2, what is the minimum size for that wet-vent segment?
An individual vent serves a 2-inch drain carrying 1 DFU. The vent is 10 feet long, entirely vertical, with no water closet or six-unit trap. Under 2025 CPC 904.1 and Table 703.2, what is the minimum vent size?
Where structural conditions do not prohibit the ordinary rise, how far above the fixture flood-level rim must a vent rise before offsetting horizontally under 2025 CPC 905.3?
Loading more…