Which code is the primary U.S. standard that an ASSE 6020 Medical Gas Inspector enforces during inspection of new medical gas piping systems?
Codes And Standards
Question · Easy
What is the primary role of an ASSE 6020 Medical Gas Inspector?
Inspector Authority
Per NFPA 99, who must perform the final verification of a medical gas system before it is placed in clinical service?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which ASTM specification covers seamless copper tube cleaned, capped, and labeled specifically for medical gas service?
Piping Materials
During an in-progress brazing inspection, the inspector observes no purge gas flowing through the copper tube while joints are being brazed. The correct response is to:
Brazing Inspection
Question · Medium
Which standard qualifies a brazer for medical gas piping joints?
Which brazing filler metal family is acceptable for joining copper-to-copper medical gas piping joints?
When the installer brazes copper tube to a bronze valve body, which brazing filler metal must be used?
Why are cadmium-bearing brazing alloys prohibited for medical gas piping?
Per NFPA 99 / CGA C-9, what is the correct identification color for medical oxygen piping?
Identification And Labeling
What is the correct CGA C-9 color identification for medical air piping?
What is the correct CGA C-9 color identification for medical vacuum piping?
Under NFPA 99, a Level 1 medical gas system is intended for:
System Categories
An ASSE 6020 inspector reviewing a Level 1 medical oxygen source must confirm the source has at least:
Source Equipment
DISS (Diameter Index Safety System) threaded connections are used on medical gas outlets to:
Outlets And Terminals
Per NFPA 99, the initial pressure test on medical gas piping must be at least:
Acceptance Testing
Under NFPA 99, the medical gas standing pressure test must be performed at working pressure for a minimum of:
What is the purpose of the cross-connection test during medical gas system acceptance?
During the high-flow particulate purge, the verifier expels gas through each outlet onto a white cloth. The inspector witnesses the test. The test passes only when:
Per NFPA 99, the maximum allowable dew point for medical air at 50 psig is:
Gas Purity
Question · Hard
Per NFPA 99, the maximum allowable carbon monoxide concentration in medical air is:
Per NFPA 99, the maximum allowable carbon dioxide concentration in medical air is:
Master alarms in a medical gas system must annunciate at a minimum of:
Alarms
Area alarms in a medical gas system monitor:
When inspecting a medical air compressor system, which intake location is acceptable?
Inspection of bulk liquid oxygen siting falls primarily under which code in addition to NFPA 99?
What is WAGD?
System Types
Zone valves on a medical gas system must be:
Valves
Per NFPA 99, the recommended nitrogen purge flow rate during brazing is:
Brazing proficiency for medical gas installers must be re-verified at a maximum interval of:
During pre-construction submittal review, the ASSE 6020 inspector should verify that the design includes:
Documentation Review
An ASSE 6020 inspector finds that the installer's brazing log records the same brazer ID for joints made on dates the brazer was not on site. The correct response is to:
Which document must the installer produce after completing the system, and which the inspector must verify before AHJ acceptance?
An ASSE 6020 inspector observes the installer reusing ASTM B819 copper tube that was previously stored uncapped on an open jobsite shelf for several months. The correct response is:
Which gas service is associated with the color blue under CGA C-9 / NFPA 99 labeling?
Which gas service is associated with the color black under CGA C-9 / NFPA 99 labeling?
Which gas service is associated with the color gray under CGA C-9 / NFPA 99 labeling?
An inspector reviewing a Level 2 medical gas system can expect which key difference from a Level 1 system?
An ASSE 6020 inspector visits the site and finds the installer using a propane torch on copper-to-copper joints. The correct response is to:
The installer's brazing log must include, at minimum:
Quick-connect outlet adapters in medical gas systems are gas-specific by:
If the installer's initial pressure test passes but a leak is found during the 24-hour standing pressure test, the inspector should:
Which document does the ASSE 6030 verifier deliver to the 6020 inspector and AHJ at the end of the verification?
Source/main and riser valves on medical gas systems must be located:
Inspecting an oxygen manifold installation, the inspector confirms the manifold is sized so that:
Inspecting a duplex medical air compressor system, the inspector confirms that:
Which test confirms that the gas piped to an oxygen outlet is in fact oxygen and not nitrogen, nitrous oxide, or air?