A CP Technician measures native potential = -0.550 V CSE, on-potential = -1.050 V CSE, instant-off = -0.920 V CSE, and final depolarized = -0.600 V CSE. Which criteria are met?
- ANeither the -850 mV polarized nor 100 mV shift criterion
- BBoth the -850 mV polarized criterion (-0.920 V meets) and the 100 mV shift criterion (|0.…
- COnly the 100 mV shift
- DOnly the -850 mV criterion