# City & Guilds 2922-34 Solar PV Exam: What to Practise for Units 301 and 302

> Find out what both City & Guilds 2922-34 assessments require, how to confirm your permitted books, and how to prepare for the online test and practical separately.

- Canonical: https://open-exam-prep.com/blog/city-guilds-2922-34-solar-pv-exam
- Published: 2026-11-27
- Updated: 2026-11-27
- Author: OpenExamPrep Editorial Team
- Publisher: OpenExamPrep, free exam prep

## Key facts

- The City & Guilds 2922-34 Solar PV award requires passes in both Unit 301 and Unit 302.
- City & Guilds specifies 30 multiple-choice questions in 60 minutes for the 2922-301 solar PV knowledge test.
- City & Guilds sets the 2922-301 solar PV knowledge-test pass mark at approximately 75% in handbook version 1.3.
- City & Guilds allocates 16 of the 30 Unit 301 questions to solar PV design and installation considerations.
- Unit 302 is a practical assignment marked by the training centre and externally quality-assured by City & Guilds.
- City & Guilds approves the 2922-34 Solar PV qualification for practising electricians aged 18 or over who meet the entry rules.
- The City & Guilds 2922-34 qualification handbook gives each learner registration a validity period of 12 months.
- City & Guilds publishes 31 December 2027 as the last registration date for the 2922-34 Solar PV qualification.
- City & Guilds' public 2922 qualification page does not specify the Amendment 4 changeover date for the 2922-301 test.

**To earn the City & Guilds 2922-34 Solar PV award, you must pass both assessments.** Unit 301 is a 30-question, 60-minute open-book knowledge test on e-volve, with a pass mark of approximately 75%. Unit 302 is a separate practical assignment. Before buying books or sitting the test, confirm the exact editions for your booking: the current UK wiring standard and the versions named in the published exam handbook are not the same.

Start with the [free 2922-34 practice questions](https://open-exam-prep.com/practice/uk-city-guilds-2922-l3-solar-pv) if you've already booked. If you're choosing a course, use the booking questions below before paying for a place or a book.

| Assessment | What City & Guilds requires | What to rehearse |
| --- | --- | --- |
| Unit 301: online knowledge test | 30 multiple-choice questions in 60 minutes; pass/fail, with the pass mark set at approximately 75%. City & Guilds sets and marks it. | Choose the relevant reference, interpret it and apply it to the facts given. |
| Unit 302: practical assignment | City & Guilds sets the assignment; your centre marks it and City & Guilds quality-assures the marking. | Demonstrate your work in supervised training, record evidence and explain your decisions. |

Source: [City & Guilds 2922-34 qualification handbook, version 1.3, pp. 14–15](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/centre-documents/2922-34-level-3-solar-pv-qualification-handbook-v1-3-pdf.pdf). The approximate pass mark isn't a promise that a particular raw score will be enough. A strong Unit 301 result doesn't make up for a Unit 302 fail.

## Which books can you take into 2922-301?

**Ask your centre which editions are permitted for your specific sitting.** City & Guilds' public materials establish which two publications are meant, but they don't give a clear 2922-301 changeover date for the wiring-regulations edition.

| Source | What it tells you |
| --- | --- |
| [2922-34 handbook, p. 15](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/centre-documents/2922-34-level-3-solar-pv-qualification-handbook-v1-3-pdf.pdf) | Lists the second edition of the IET *Code of Practice for Grid-connected Solar Photovoltaic Systems*, BS 7671:2018+A2:2022 including Amendment 3:2024, and a calculator. |
| [Electrotechnical permitted materials guide, May 2026](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/additional-documents/electrotechnical_permitted_reference_materials_v3-1-pdf.pdf) | Lists both publications for 2922-301 without edition numbers. Its general rule is to use current editions unless specifically stated otherwise. |
| [City & Guilds 2922 qualification page, updated 25 May 2026](https://www.cityandguilds.com/qualifications-and-apprenticeships/building-services-industry/electrical-installation/2922-small-solar-photovoltaic-systems) | Says affected assessment documents will be updated for Amendment 4, but gives no specific 2922-301 switch date. |
| [IET wiring-regulations edition checker](https://electrical.theiet.org/bs-7671-18th-edition-wiring-regulations/ensure-you-are-up-to-date-with-bs-7671) | Identifies BS 7671:2018+A4:2026 as the current UK standard after the transition ended on 15 October 2026. That is not the changeover date for your exam. |

When you contact your centre, give them the **2922-301** test code and your proposed sitting date. Ask for the exact BS 7671 amendment and PV Code edition, whether the centre provides paper copies, and what page tabs, highlighting and calculator you can use. Keep the reply with your booking and practise with those editions. Don't assume a newer book is automatically allowed, or that the edition named in an older handbook is still the one for your sitting.

The City & Guilds permitted-materials guide allows a non-programmable scientific calculator and rules out electronic copies for externally marked assessments such as e-volve tests. Its general marking rules allow some page references and highlighting, but not inserted personal notes, added formula sheets or handwritten procedures. Check the centre's instructions before marking up a book. If you normally work from a digital subscription, rehearse with the paper copies you'll actually use so that you aren't relying on search.

## What to revise first for the Unit 301 test

The [official Unit 301 specification](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/centre-documents/2922-34-level-3-solar-pv-qualification-handbook-v1-3-pdf.pdf) assigns **25 of 30 questions** to PV characteristics and design together. That's where most of your question practice should go. Use the counts to plan revision; don't mistake them for a list of the individual questions you'll see.

| Handbook outcome | Questions | A useful revision drill |
| --- | ---: | --- |
| LO4: Design and installation decisions | 16 (53%) | In a fictional design, identify the limiting value or condition, then explain why it changes the answer. Practise both equipment-data interpretation and reference lookups. |
| LO3: PV characteristics, components and system layouts | 9 (30%) | Sketch a basic system from modules to AC output. Explain what changes when modules are in series versus parallel, and distinguish the roles of the module, inverter and any storage. |
| LO6: Microgeneration and electrical energy storage | 3 (10%) | Given a household objective, explain how self-consumption, export and backup differ. Don't assume the presence of a battery means the system can supply the property during a grid outage. |
| LO1: Documentation and legislation | 2 (7%) | Given an information need, name the right source: wiring standard, PV Code, equipment manufacturer's instructions or network operator guidance. Not every useful document is an exam-room reference. |

LO2 (working safely) and LO5 (testing, commissioning and handover) are practical outcomes. Neither has a separate allocation in the Unit 301 table. That doesn't make safety irrelevant to a knowledge question about an installation decision, and it certainly doesn't make a mock score evidence of practical competence.

### A short design drill: find the condition that changes your answer

An original paper exercise gives you eight identical modules in series. Each module has an open-circuit voltage of 41 V under one stated condition and 46 V at the colder condition specified in the question. The inverter's stated maximum DC input voltage is 350 V. An answer choice argues that the string is acceptable because eight times 41 V is 328 V.

That answer uses the wrong condition for the limit check. Eight times 46 V is **368 V**, which exceeds the stated maximum by **18 V**. The useful revision habit is to label each value before reaching for the calculator: module or string, operating or open-circuit voltage, and the condition it applies to. If you picked 328 V, log the error as *wrong condition*, not *bad arithmetic*. This exercise checks one constraint with supplied figures; it isn't a string-design procedure or an assessment item. Use the [study guide section on PV voltage and current](https://open-exam-prep.com/study-guides/uk-city-guilds-2922-l3-solar-pv/dc-ratings-protection/dc-multipliers) for the wider topic.

### Run a timed set and diagnose the misses

Ask your centre about access to the official sample paper and mark scheme listed under **Assessment materials** on the [2922 qualification page](https://www.cityandguilds.com/qualifications-and-apprenticeships/building-services-industry/electrical-installation/2922-small-solar-photovoltaic-systems). The listed files are password-protected. If your centre hasn't made them available yet, use a fresh set from the [independent 2922-34 practice bank](https://open-exam-prep.com/practice/uk-city-guilds-2922-l3-solar-pv). It helps you rehearse recall and reasoning; it isn't the official paper or a prediction of the live questions.

For an independent timed session, try 30 fresh questions in 60 minutes with the paper copies and calculator confirmed by your centre. Two minutes per question is an average, not a rule. Note which questions needed a lookup and which answers were guesses, even if the guess was correct. Afterwards, mark each miss with one cause and pick the corresponding fix:

| What went wrong? | What to change before the next set |
| --- | --- |
| You couldn't find the right reference quickly. | Pick three scenarios and name the likely source before opening any book. Use its contents and index to find the relevant section, then repeat the lookup without a digital search. |
| You found the right page but missed an exception or condition. | State the condition in your own words and explain what fact in the question makes it apply. |
| The numerical answer looked plausible but used the wrong input. | Label each value and its unit before you calculate. For a paper exercise like the one above, show which stated limit you're comparing it against. |
| You answered from memory and got lucky. | Redo the question without the answer choices and explain why one plausible alternative fails. |

Retest with fresh questions after you fix the biggest recurring error. Repeating the same set can tell you what you remember about that set; it can't tell you whether you can find and apply an unfamiliar rule under time pressure.

## Unit 302: rehearse the evidence, not just the explanation

Start by asking for the current candidate instructions and a supervised practice opportunity. City & Guilds' [handbook](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/centre-documents/2922-34-level-3-solar-pv-qualification-handbook-v1-3-pdf.pdf) describes risk assessment and method statements under LO2, and inspection, testing, commissioning, handover and maintenance under LO5. The separate candidate pack controls the actual instructions, so use the outcomes below as a rehearsal framework, not a claim about task order, practical duration or a marking checklist.

1. **Explain what can still be live.** In a simulated safety discussion, don't accept “the AC supply is off” as evidence that PV DC is dead. The handbook notes that modules can generate in daylight. Have your instructor ask what the risk assessment and method statement must account for, and practise only in the supervised setup they specify.
2. **Make your evidence traceable.** In the training bay, ask how to identify the equipment or circuit to which a result belongs and where to record an observation. Have someone else read your training record back to you. If they can't tell which result belongs to which part of the system, improve the record rather than relying on your memory.
3. **Explain a handover in ordinary language.** Use the training documents to describe normal operation, where to find the drawings and test records, and what a customer should do if they notice unexpectedly poor performance. The [study guide section on handover and maintenance](https://open-exam-prep.com/study-guides/uk-city-guilds-2922-l3-solar-pv/testing-commissioning/handover-and-maintenance) is a useful follow-up before a supervised session.

Try this tabletop check: your fictional handover folder contains a drawing and a completed-looking results sheet, but two results have no circuit identifiers. A colleague wants to hand it over because the numbers “look about right”. Explain why plausible numbers don't repair missing traceability. Identify what must be checked against the drawing and the original evidence; never fill in missing identifiers by guessing. That's the distinction to practise before assessment: can someone else understand and verify the work you record?

## Before paying for a course: confirm entry and booking details

This is CPD for practising electricians, not a route into the trade from scratch. The [handbook's entry rules, p. 10](https://www.cityandguilds.com/-/media/productdocuments/building_services_engineering/electrical_installation/2922/centre-documents/2922-34-level-3-solar-pv-qualification-handbook-v1-3-pdf.pdf) specify a minimum age of 18 and list accepted electrotechnical qualifications and equivalences or an eligible JIB or SJIB ECS Gold Card. There are also listed routes specific to Scotland and Wales. For qualifying awards achieved more than five years before starting, the handbook calls for evidence that you've kept current by holding the latest Wiring Regulations qualification. Send your evidence to the centre before paying, particularly if you have a historical qualification or are relying on a card rather than a recent certificate.

- **Confirm what you're buying.** The qualification is **2922-34**, the Level 3 Award in the Installation and Maintenance of Small Solar Photovoltaic Systems. The separate [2923-34 electrical energy storage award](https://www.cityandguilds.com/qualifications-and-apprenticeships/building-services-industry/electrical-installation/2923-small-electrical-energy-storage-systems) isn't interchangeable with it, even though battery storage appears in the 2922 syllabus.
- **Get a complete quote and timetable.** Ask whether tuition, registration, the Unit 301 sitting and the Unit 302 assignment are included, and what any resit costs. Confirm where or how Unit 301 is invigilated, where you'll do the practical, and whether any access arrangements must be set up in advance. Don't infer a national candidate fee or delivery arrangement from a provider's package.
- **Distinguish the deadlines.** The [qualification listing](https://www.cityandguilds.com/qualifications-and-apprenticeships/building-services-industry/electrical-installation/2922-small-solar-photovoltaic-systems) shows 31 December 2027 as the last registration date and 31 December 2030 as the last certification date. The handbook separately says an individual learner's registration is valid for 12 months. Ask your centre to confirm your own registration date and schedule both assessments in that window.

If the test is your weaker half, take a timed set and fix the first repeated error. If the practical is your weaker half, arrange a supervised run-through and ask for feedback on one safety decision and one piece of evidence. Use the [free 2922-34 study guide](https://open-exam-prep.com/study-guides/uk-city-guilds-2922-l3-solar-pv) for the topic behind each miss. The aim is to walk into two different assessments having practised the two different things they require.

## FAQ

### How many questions are on the City & Guilds 2922-301 exam?

Unit 301 has 30 multiple-choice questions and lasts 60 minutes. The qualification also requires a separate Unit 302 practical pass.

### What is the City & Guilds 2922-34 pass mark?

City & Guilds sets the Unit 301 knowledge-test pass mark at approximately 75%. You must also pass the practical assignment, Unit 302, to earn the award.

### Can I use BS 7671 Amendment 4 in the 2922-301 exam?

Confirm with your centre for your booked sitting. Amendment 4 is the current UK wiring standard, but the public City & Guilds 2922 notice does not give a 2922-301 changeover date.

### Is the City & Guilds 2922-301 test open book?

Yes. The two permitted publications are the IET Wiring Regulations and the IET solar PV Code of Practice. Confirm the editions, paper copies and permitted markings with your centre before the sitting.

### How do I get the official 2922-34 sample paper?

City & Guilds lists the sample question paper and mark scheme under Assessment materials on the 2922 qualification page. The listed PDFs are password-protected; ask your training centre for authorised access.

### Can I take 2922-34 if I am new to electrical work?

It is continuing professional development for practising electricians, not an entry route into electrical work. Applicants must be 18 or over and meet City & Guilds' electrotechnical entry requirements.

### Does 2922-34 count as the City & Guilds battery storage award?

No. The 2922-34 syllabus includes electrical energy storage in a solar PV context, but City & Guilds 2923-34 is the separate qualification for small electrical energy storage systems.

## Study free on OpenExamPrep

- City & Guilds 2922-34 Level 3 Award in the Installation and Maintenance of Small Solar Photovoltaic Systems: [Practice questions](https://open-exam-prep.com/practice/uk-city-guilds-2922-l3-solar-pv) · [Study guide](https://open-exam-prep.com/study-guides/uk-city-guilds-2922-l3-solar-pv)